Let's Chat

Any Query ?

Gradient High-performance Liquid Chromatography NHLC-100

Gradient High-performance Liquid Chromatography NHLC-100

Gradient High-performance Liquid Chromatography NHLC-100

High-performance Liquid chromatography NHLC-100 is a gradient pump liquid chromatography system. It involves a superior high-pressure pump that aids in the accurate solvent delivery with high-precision and low-fluctuation. The UV detector assembly enhances stronger detection capabilities of the system. This leads to efficient separation of the desired pharmaceutical compound and obtains high operation reliability for extended time intervals.

Specifications
High pressure pump 2
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i
Flow rate range 0.001-9.999mL/min
Flow rate accuracy ≤±0.5% (1mL/min, water, room temperature)
Flow rate precision RSD≤0.08% (1mL/min, water, room temperature)
Pressure range ≤42MPa
Detector UV
Lamp Deuterium lamp
Wavelength range 190-700nm
Baseline noise ≤8×10-6AU
Baseline drift ≤1×10-4AU/h
Detection Limit 4×10-9 g/ml (Naphthalene/methyl alcohol solvent)
Wavelength accuracy ±1nm
Software EasyChrom Chromstation
Features
Applications

It is used multidisciplinary to split a mixture of compounds in the fields of analytical chemistry, biochemistry, industrial purposes and Research & development studies.

Optional Accessories

Accessories No Name
1 Autosampler
2 Column Oven

Buy Now

Isocratic High-performance Liquid Chromatography NHLC-200

High pressure pump 1
Column C18
Column dimension 250cm×4.6cm
Injection valve 6-way ,7725i

Quaternary High Pressure Liquid Chromatography NHLC-301
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)
Quaternary High Pressure Liquid Chromatography NHLC-302
Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)

Quaternary High Pressure Liquid Chromatography NHLC-303

Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)

Quaternary High Pressure Liquid Chromatography NHLC-300

Quaternary Pump Specifications:- Flow rate Range 0.001-10.000mL/min, 0.001mL increments
Flow accuracy ≤±0.2% (1.00ml/min, H2O, R.T., 8.5MPa)
Flow precision RSD≤ 0.06% (1.00ml/min, H2O, R.T., 8.5MPa)
Maximum pressure 50MPa (0.001mL/min-5.000mL/min) 20MPa (5.001mL/min-10.000mL/min)

Analytical High-performance Liquid Chromatography NHLC-400
High-Pressure Constant Flow Pump
Flow Range 0.001 to 10.000 mL/min (step 0.001 mL/min)
Accuracy ≤±0.2%
Precision ≤0.06% RSD
Pressure Range 0 to 45 MPa
Power AC 220 V±10%, 50 Hz/80 W
Dimension (L × W × H) 420 × 300 × 175 mm
Weight 12 kg
Low-Pressure Quaternary Constant Flow Pump
Flow Range 0.001 to 10.000 mL/min (step 0.001 mL/min)
Gradient Accuracy ≤±1%
Retention Time Repeatability ≤0.1%
Maximum Working Pressure 63 Mpa
Communication Methods UDP Network Communication
Mixed Volume 750μL
Power AC 220 V±10%, 50 Hz/100 W
Dimension (L × W × H) 400 × 300 × 180 mm 
Weight 15 kg
UV-Vis Detector
Linear 2.0 AU
Wavelength Range 190 to 700 nm
Noise ≤± 0.5,105 AU
Drift ≤1.0 × 104 AU/h
Cell Analytical: Optical path 10 mm, 11μL Semi-prep scale: Optical path 2 mm, 6μL
Power AC 220V±10%, 50 Hz/100 W
Dimension (L × W × H) 420 × 300 × 175 mm
Weight 16 kg
Diode Array Detector
Linear ≥2.0 AU
Wavelength Range 190 to 800 nm
Noise ≤±1.0M05 AU
Drift ≤2.0 × 104 AU/h
Power AC220 V±10%, 50 Hz/180 W
Dimension (L × W × H) 500 × 300 × 175 mm