Any Query ?
Temperature And Humidity Test Chamber NTHC-200
Temperature and Humidity Test Chamber NTHC-200 is designed for precision testing of material resilience. It tests the samples under higher temperature and humidity conditions. Crafted from corrosion-resistant stainless steel, ensuring durability and reliability. Its robust construction not only safeguards the chamber but also guarantees consistent performance over extended periods.
Capacity | 100 L |
Temperature range | (-20) ℃ to 150 ℃, (-40) ℃ to 150 ℃, (-70 ) ℃ to 150 ℃ |
Temperature cooling rate | 1 ℃ / min |
Temperature heating rate | 3 ℃ / min |
Temperature fluctuations | ± 0.5 ℃ |
Temperature deviation | ± 2.0 ℃ |
Humidity range | 20 % to 98 % R.H |
Humidity deviation | ± 2.5 % RH |
High temperature | 180 ℃ |
Lowest humidity | 10 % RH |
Internal dimension (D × W × H) | 400 × 500 × 500 mm |
Overall dimension (D × W × H) | 860 × 1050 × 1620 mm |
Temperature and Humidity Test Chamber is widely used in basic and advanced research, pharmaceutical industries, chemical industries, food and beverage.
Capacity | 50 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 100 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 150 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 225 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 408 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 500 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 800 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 1000 L |
Temperature range | -40°C ~ 150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 50 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 100 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 150 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 225 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 408 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 500 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 800 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 1000 L |
Temperature range | -60°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 50 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 100 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 150 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 225 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 408 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 500 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 800 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Capacity | 1000 L |
Temperature range | -70°C ~150°C |
Humidity range | 20%RH ~ 98%RH |
Temperature fluctuation | ± 0.5°C |
Temperature range | Without illumination 0 to 65˚C; With illumination: 10-65 ˚C |
Temperature resolution ratio | 0.1 ˚C |
Temperature motion | +1 ˚C |
Temperature uniformity | +1.0 ˚C |
Temperature range | Without illumination 0 to 65˚C; With illumination: 10-65 ˚C |
Temperature resolution ratio | 0.1 ˚C |
Temperature motion | +1 ˚C |
Temperature uniformity | +1.0 ˚C |
Temperature range | Without illumination 0 to 65˚C; With illumination: 10-65 ˚C |
Temperature resolution ratio | 0.1 ˚C |
Temperature motion | +1 ˚C |
Temperature uniformity | +1.0 ˚C |
Labnics Drug Test Chamber are engineered to ensure precise environmental conditions for the stability testing of pharmaceutical products. They feature a user-friendly interface with a lock function for secure and easy operation. Equipped with a high-quality compressor for failure-free continuous operation. They maintain precise humidity levels to simulate actual storage environments. Our chamber are constructed with high-quality materials for durability and longevity.
Volume | 500 L |
Temperature Range | 0 to 70 °C |
Temperature Resolution | 0.1 °C |
Temperature Uniformity | ≤ 0.5 °C |