Labnics Air Flow Capture Hood NACH-200 measures air volume from 100 to 3500 m³/h with ±5 % F.S. accuracy. Air volume resolution reaches 1 m³/h on this air capture hood. The temperature range runs from 0 to 60 °C with ±0.5 °C accuracy, and the humidity range runs from 0 to 100 %RH. Up to 5,000 results are stored on this air balancing hood. Bluetooth printing sends results from this capture hood to a printer. This touchscreen balometer shows air volume, temperature, and humidity together, and works as an electronic balometer.
$3,412.00
| Air Volume Range | 100 to 3500 m³/h |
| Air Volume Accuracy | ±5 % F.S |
| Air Volume Resolution | 1 m³/h |
| Display | Touch screen |
| Temperature Range | 0 to 60 °C |
| Temperature Accuracy | ±0.5 °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 0 to 100 %RH |
| Humidity Accuracy | ±0.1 %RH |
| Humidity Resolution | 0.1 %RH |
| Data Storage | 5000 results |
| Printing | Bluetooth printer |
| Hood Sizes | 570 × 570 mm; 830 × 830 mm |
| Hood Material | Polyester |
| Tripod | Standard |
| Power Supply | AC 220 V / 110 V, 50/60 Hz; DC 9 V |
| Operating Environment | 5 to 35 °C, 30 to 70 %RH |
| Storage Environment | −30 to 45 °C, 0 to 70 %RH |
Wide Measuring Range — Reads low to high airflow outlets
Touch Screen Display — Air volume, temperature, and humidity in one view
Bluetooth Printing — Sends results to a printer for records
Data Storage — Keeps results in memory for later review
Polyester Hoods — Interchangeable hoods fit varied supply and exhaust terminals
Tripod Support — Standard tripod holds the hood steady during readings
| HVAC Laboratories | HEPA Filtration Laboratories | Cleanroom Laboratories | Laminar Flow Laboratories |
|---|---|---|---|
| Measures supply and exhaust air volume at HVAC duct terminals to balance airflow. | Checks air volume at HEPA outlets to confirm filtered air delivery. | Reads air volume at fan filter units to confirm airflow output across a room. | Verifies airflow delivery from laminar flow systems during routine checks. |
| Accessories No | Name |
| 1 | Wind cover 570 x 570 mm one set 830 x 830 mm |
| 2 | Battery and Charger |
| 3 | Adjustable Bracket |
| 4 | Built-out Printer |
1: Why should the Air Flow Capture Hood NACH-200 be placed below air conditioning or air purifying units?
The Air Flow Capture Hood NACH-200 is specifically designed to measure airflow, temperature, humidity, and pressure directly at the output of HVAC or purification systems. Placing it beneath these units ensures accurate and localized readings essential for system evaluation.
2: How does the Air Flow Capture Hood NACH-200 support Cleanroom and GMP compliance?
This Air Flow Capture Hood NACH-200 includes built-in data acquisition software that allows secure data storage and analysis. This capability supports environmental monitoring and documentation required for Cleanroom and GMP standards.
3: Can the Air Flow Capture Hood NACH-200 be used for extended periods without external power?
Yes, the Air Flow Capture Hood NACH-200 is equipped with built-in rechargeable batteries that provide up to 30 hours of continuous operation, making it ideal for long-duration testing tasks.
4: What type of display does the Air Flow Capture Hood NACH-200 offer?
Our Air Flow Capture Hood NACH-200 comes with a large touch screen LCD display that provides clear visibility of measured parameters and easy navigation of functions during use.
5: What should I do if the Air Flow Capture Hood NACH-200 does not register airflow correctly?
If the Air Flow Capture Hood NACH-200 is not detecting airflow, ensure that the nylon wind cover is properly secured, the anemometer is correctly adjusted using the fixed helix, and the hood is aligned directly below the airflow outlet. Also, confirm that the battery is charged and the support rod is stable.
6: Can the Air Flow Capture Hood retain data after it is turned off?
Yes, the Air Flow Capture Hood has built-in memory retention that preserves all recorded data even after the device is powered off. This feature ensures users do not lose critical measurements and can easily access them later for analysis or reporting.
7: How should the Air Flow Capture Hood be positioned for accurate airflow detection?
To ensure accurate airflow measurement, the Air Flow Capture Hood should be placed directly under an air outlet using the adjustable lifting rod and detachable micrometer. The nylon wind cover helps capture airflow efficiently by creating a secure enclosure over the outlet.
8: What should I do if the Air Flow Capture Hood shows inconsistent airflow readings?
Check that the wind cover is properly sealed and that the hood is evenly aligned with the air outlet. Make sure the anemometer is correctly adjusted and free from obstruction. Also, verify the unit is placed on a stable surface using the lifting rod for proper support.
9: What display and connectivity options are available in the Air Flow Capture Hood?
The device features a user-friendly large touch screen LCD that displays real-time data clearly. It also includes USB and printer interfaces, allowing users to transfer digital records or print results directly during field assessments.