WhatsApp
Laser Particle Counter NLPC-200

Laser Particle Counter NLPC-200

Laser Particle Counter NLPC-200 is a device used to measure the cummulative and differential size distribution of dust particles per unit volume in clean environment. Using the laser diode, the instrument measures the light that is redirected or absorbed by the particle. A highly accurate built-in sensor displays the measurement on a well-lit LCD display along with temperature and humidity readings. Designed with 6 measurement channels, laser particle counter is a perfect tool for measuring and monitoring airborne contamination sources in hospitals or healthcare facilities.


Catalog

Specifications

Light source Laser diode (lifetime greater than 35000 hours)
Particle channel 0.3, 0.5, 1, 3, 5, 10 µm
Sampling period 1 to 10000 (s) time-delay: 0 to 99 (s) Self-cleaning time: 10 min
Sampling flow 2.83 L / min (0.1 cfm) Imported pump
Test mode Single, repetitive, continuous, computing, remote
Count mode The cumulative values, the difference and density
Working time 6 hours (Provide a fuel gauge of remaining battery capacity)
Display LCD real time display, a period, the concentration of the real-time display, can display time, date, measurements, temperature and humidity, room number, number of sampling points, sampling battery, state parameters, such as 95 % UCL computing, can directly show the particle concentration m3
Rechargeable battery Lithium ion battery, 7.4 V, 2200 mAh
Ambient Temperature 10 to 40 °C (50 to 104 °F)
Humidity 20 to 90 % RH
Atmospheric pressure 86 to 106 kPa
UCL set Sampling number (A): 2 to 9 point set. Each point of sampling time: (L) 2 to 9 times set Measurement setup: 0 to 999
UCL report forms Meet the standards of ISO 14644-11
Data store Can store 1000 groups data (Circulation buffer) ( Including particle data, environment data, year month day time, sampling number, data port), The data is not lost when power is cut off.
Communication interface RS 230, 9600 Baud rate
Zero count Instrument with level alarm function, can to dean room grade 100, grade 1000, grade 10000, grade 100000, grade 300000, grade 1000000 with excessive alarm and low battery voltage alarm
Superposition errors 5 %, 2,000,000 grain / cubic feet
Print function Cab connect the external printer
Standard configuration Suitcase charger sampling head nul filter RS232 connecting in CD for computer communication software
Sampling position number 1000 groups
Measuring repeated relative deviation ≤ ± 10 %
Weight 1 kg
Overall dimension 220×40×120 mm
Power supply External AC power adapter, AC: 100 V to 245 V, 50/60 Hz to DC: 7.4 V, 1 A

Features

  • Distribution error of particle size is 0.5 µm 5 µm ≤ ± 20 %
  • Sampling flow and error 2.83 L / min ≤ ± 5 %
  • Maximum limit to measure the particle concentration ≤ 30 k / L
  • Measurement repeat relative deviation ≤ ± 10 %
  • Indication error of particle concentration 0.5 µm ≤ ± 20 %
  • Range of particle size measured: 0.3, 0.5, 1, 3, 5, 10 µm, divided into 6 particle size channel
  • Simple, fast operation with two front-panel buttons
  • Self-cleaning time ≤ 10min
  • Bluetooth printing (optional) is used to print the data required
  • Colour LCD touchscreen is launched for better enhancement
  • Rubber sampling head: - to insure the service life of the sensor

Applications

  • Laser Particle Counter is used in various fields such as electronics, optical, chemical, food, cosmetics, medicine, biological products, aerospace and other departments for public health.

Ask Expert

Relative Models Of Laser Particle Counter

Laser Particle Counter NLPC-202

Particle Channel 0.3,2.5,10 μm
Mass Concentration PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3
Flow Rate 0.1 ft³ (2.83 L/min)
Catalog

Laser Particle Counter NLPC-201

Particle Channel 2.5,10 μm
Mass Concentration PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3
Resolution 1 ug/m3
Catalog

Laser Particle Counter NLPC-203

Particle Channel 0.3, 0.5, 1.0, 2.5, 5.0, 10 μm
Mass Concentration PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3
Flow Rate 0.1 ft³ (2.83 L/min)
Catalog

Airborne Particle Counter

Airborne Particle Counter NAPC-200

Flow Rate 2.83 L/min (Imported Pump)
Size Channels 0.3, 0.5, 1, 3, 5, 10 µm
Sample Time 1 to 10 min
Catalog

Airborne Particle Counter NAPC-300

Flow Rate 28 .3 L/min (Imported Pump)
Size Channels 0.3, 0.5, 1, 3, 5, 10 µm
Light Source Laser Diode (30, 000 hours Mean Time Between Failures)
Catalog
Airborne Particle Counter NAPC-400
Flow Rate 50 L / min import sampling pump
Sample Time Between 6 to 999999 s optional (Selectable)
Alarm Class
Catalog

Liquid Particle Counter

Liquid Particle Counter NLPC-100
Particle size range 0.8 to 600 µm (calibrated according to 1-100um or 4-70um(c))
Sensitivity 0.1μm
Detection channels 8 to 64 channels are optional, and the particle size can be set arbitrarily
Catalog

Liquid Particle Counter NLPC-101

Particle Size Range 0.2 to 2 μm
Detection Channels 16
Maximum Concentration 10000 particles/ml
Catalog

Laser Particle Size Analyzer

Automatic laser particle size analyzer NLPA-100

Test range 0.1 μm to 800 μm
Number of detector channels 70
Accuracy error 1% (National standard sample D50 value)
Catalog

Portable Oil Particle Counter

Labnics Portable Oil Particle Counter boasts a wide measurement range, capable of detecting particles making it versatile for different oil types. Our particle counters are integrated with optical or laser sensors to ensure reliable and repeatable measurements. They are designed for efficient and accurate monitoring of oil contamination levels in various industries. These are equipped with a user-friendly touchscreen interface, enabling quick navigation and real-time monitoring. Features built-in data logging and storage capabilities allowing users to track contamination levels over time and generate detailed reports. These are crafted with durable materials and withstand harsh environments, maintaining reliable performance.

Portable Oil Particle Counter NPOC-100
Particle Size Range 0.8 to 600 µm
Detection Channel 8 channels
Sampling Volume 0.2 to 1000 mL
Catalog
Labnics © 2025. All Rights Reserved.