Airborne Particle Counter NAPC-200
Airborne Particle Counter NAPC-200 is an analytical instrument designed to evaluate the number and size distribution of particulate matter suspended in a cleanroom environment. It is equipped with a laser diode as a light source and various size channels that enable to achieve measurement of a wide range of bio-contaminants. The data transmission interface feature allows crucial monitoring and assessment of the air quality standards as per the GMP guidelines.
Flow Rate | 2.83 L/min (Imported Pump) |
Size Channels | 0.3, 0.5, 1, 3, 5, 10 µm |
Sample Time | 1 to 10 min |
Zero Count & le | 10 min |
Location Labels | 0 to 999 |
Printer | Built-in Thermal Printer |
Alarm | 100, 1000, 10000 Class |
Data Storage | 1000 Samples (with PC Software) |
Light Source | Laser Diode (30, 000 hours Mean Time Between Failures) |
Maximum Rated Particle Concentration | 35000 particles/ L ( µM ) |
Operating Time | 8 hours |
Environment Temperature | 10°C to 35°C |
Humidity | 20 % to 75 % RH |
Atmosphere Pressure | 86 kPa to 106 kPa |
Display | LCD |
Power Source | AC 220 V ± 10 %, 50 Hz |
Max. Power Consumption | 10 W |
Weight | 4.5 kg |
It is widely used in the field of Quality control department in Pharmaceutical sector, micro-electronics, precision machinery, optics, pharmacy and sanitation, biology, food and beverage, aerospace. Also in and scientific research department such as provincial and municipal drug testing institutes, Hospitals, Inspection institutes. etc.
Particle Channel | 0.3,2.5,10 μm |
Mass Concentration | PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3 |
Flow Rate | 0.1 ft³ (2.83 L/min) |
Deviation | 5 % ; 2,000,000 particles per ft³ |
Particle Channel | 2.5,10 μm |
Mass Concentration | PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3 |
Resolution | 1 ug/m3 |
Temperature Range | 0 °C - 50 ℃ |
Light source | Laser diode (lifetime greater than 35000 hours) |
Particle channel | 0.3, 0.5, 1, 3, 5, 10 µm |
Sampling period | 1 to 10000 (s) time-delay: 0 to 99 (s) Self-cleaning time: 10 min |
Sampling flow | 2.83 L / min (0.1 cfm) Imported pump |
Particle Channel | 0.3, 0.5, 1.0, 2.5, 5.0, 10 μm |
Mass Concentration | PM2.5: 0~500 ug/m3; PM10: 0~500 ug/m3 |
Flow Rate | 0.1 ft³ (2.83 L/min) |
Deviation | 5 % ; 2,000,000 particles per ft³ |
Test range | 0.1 μm to 800 μm |
Number of detector channels | 70 |
Accuracy error | 1% (National standard sample D50 value) |
Repeatability error | 0.5% (National standard sample D50 value) |
Particle Size Range | 0.8μm to 600μm |
Sampling Volume | 0.2 to 1000mL, interval 0.1mL |
Sampling Accuracy | Better than ±0.5% |
Sampling Speed | 5 to 80mL/min |
Particle Size Range | 0.2 to 2 μm |
Detection Channels | 16 |
Maximum Concentration | 10000 particles/ml |
Accuracy | ± 10% |