Benchtop pH Meter NBPM-201 is designed for measurement of pH and temperature. It is equipped with built-in 2-points auto buffer recognition and calibration setting. It enables automatic temperature compensation for accurate display of reading value over the entire pH range. The indicator alerts for calibration aids in maintaining the smooth functioning of a meter.
Specifications
pH measuring range | 0.00 ~ 14.00 pH |
pH resolution | 0.01 pH |
pH accuracy | ± 0.01 pH |
Temperature measuring range | 0°C~100°C |
Temperature resolution | 0.1°C |
Temperature accuracy | ± 0.5°C |
Automatic temperature compensation | 0°C~50°C |
Operating temperature | 0°C~50°C |
Power supply | AC 110/220, 50/60Hz |
Overall dimension | 210 × 204 × 64 mm |
Weight | 1.5 kg |
Features
Applications
Ask Expert
pH Specifications:- Range | (-2.000~20.000) pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH, Selectable |
Measuring Parameters | pH/mV |
pH Measurement Range | -2.00 to 18.00 pH |
pH Measurement Resolution | 0.01 pH |
Measurement range | 0 to 4000mg/L |
Measuring error | ±10% |
Cycle length | 5days |
Measuring range | 0 to 4000 mg/L |
Measuring error | ±10% |
Resolution | 2 mg/L |
Measurement range | 0-4000mg/L |
Measuring error | ±10% |
Cycle length | 5 days |
High COD Range | 20 to 10000mg/L |
Low COD Range | 2 to 150mg/L |
Accuracy for COD < 50mg/L | ≤ ±5% |
Digestion capacity | 9 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 100 mm |
Digestion capacity | 16 samples per run |
Vial capacity | 19 ml |
Vial dimension | Ф16×145 mm |
Model no | NCCA-100 |
Measuring range | k= 1 0~2000μS/cm |
Resolution | 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm |
Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.
Conductivity specifications:- Conductivity range | 0.000µS/cm ~ 1000mS/cm |
Conductivity resolution | 0.001µS/cm |
Conductivity accuracy | ± 1.0% (FS) |
Measurement Range | 0 to 400 mS/cm |
Resolution | 0.001 μS/cm to 0.1 mS/cm |
Indication Error | ±0.5% F.S |
Conductivity range | 0.000 μS/cm to 500 mS/cm |
Conductivity resolution | 0.001 μS/cm minimum, various range selection |
Conductivity accuracy | ±1.0% FS |