ICP Mass Spectrometer NICPM-100 offers ultra-low detection limits, detecting lithium below 2 ppt and indium and uranium below 0.1 ppt. It has a dual-mode detector that covers a dynamic range of greater than 9 orders of magnitude. Our system uses a high-efficiency collision reaction cell that effectively removes interferences. It features a split torch and TEC-cooled chamber for better organic solvent analysis. This system has a second argon stream that allows high-salt sample analysis without manual dilution.
$116,038.00
| Mass Range | 2 to 260 amu |
| Resolution | 0.3 to 2.0 amu (adjustable) |
| Dynamic Range | > 9 orders of magnitude |
| Background Stability | < 0.5 cps at 5 amu |
| Stability | RSD< 2% (short: 20 min) < 3% (Long: 2 hr) |
| Sensitivity | Li > 20 Mcps/ppm In > 180 Mcps/ppm U > 200 Mcps/ppm |
| Oxide and Doubly Charged Ions | Ce++/Ce+ < 3% CeO+/Ce+ < 3% |
| Detection Limits | Li < 2 ppt In < 0.1 ppt U < 0.1 ppt |
| Abundance Sensitivity | 1×10⁻⁶ (low mass), 5×10⁻⁷ (high mass) |
| Mass Axis Stability | < 0.05 amu/24h |
| Isotope Ratio Accuracy | < 0.2% (e.g., 107Ag/109Ag) |
| Consumables | Torch, pump tubes, internal std tubes (1-year supply) |
| Computer | Intel i5-8500, 8GB RAM, 1TB HDD, 23-inch monitor |
| Cooling System | 2100W cooling capacity, >2L tank |
| Printer | B/W Laser printer |
| Voltage Regulator | 15 KVA, 220V ± 1% output |
| UPS | 10 KVA, 1 hr backup |
| Power consumption | ≤ 3.5 kW |
| Power Supply | 220 V ± 10%, 50/60 Hz |
| Dimensions | 1400 × 820 × 850 mm |
| Net Weight | 225 Kg |
| Gross Weight | 505 Kg |
Real-time visualization
Automated reporting
HPLC integration
High salt tolerance
Efficient interference removal
Stable ion source
ICP Mass Spectrometer NICPM-100 delivers precise trace element analysis with high sensitivity and interference removal. It is used in the environmental monitoring of water, soil, air particulates, food, cosmetics, semiconductors, and textiles.
High matrix and high salt sampling system × 1Set
TEC cooling module (Scott) × 1Set
Engineering installation package × 1Set
Water, gas, and electricity installation system × 1Set
Mechanical pump × 1Set
Cooling Circulating Water Machine (Chiller)
Autosampler
Autosampler Installation Package
1: Can ICP Mass Spectrometer NICPM-100 handle high-salt samples?
Yes, it allows direct injection of samples with up to 10% salt content due to its advanced online dilution and optimized ion interface design.
2: Does the ICP Mass Spectrometer NICPM-100 require frequent maintenance?
Minimal maintenance is needed because the NICPM-100 is designed with a self-cleaning ion lens that prevents contamination build-up, reducing the need for manual cleaning.
3: What are the key features and capabilities of the software included with the ICP Mass Spectrometer NICPM-100?
The software offers real-time monitoring of key parameters, automatic tuning for optimized performance, and intuitive visual dashboards. It also includes built-in QC functions and customizable reporting tools to streamline analysis and ensure data accuracy.
4: Does the system support HPLC integration?
Yes, it integrates with HPLC systems, enabling synchronized control and data acquisition for speciation analysis. This allows real-time peak identification, retention time tracking, and precise quantification of element species in complex samples.
5: Is the ICP Mass Spectrometer NICPM-100 suitable for organic solvent analysis?
Yes, it supports direct analysis of solvents like methanol and acetonitrile due to its stable ICP source and TEC cooling.
6: What types of samples can be analyzed using ICP Mass Spectrometer?
Our ICP Mass Spectrometer can analyze liquids, digested solids, environmental samples, biological fluids, food products, and any material that can be converted into a solution.
7: What is the detection limit of an ICP Mass Spectrometer?
ICP Mass Spectrometer instruments can detect elements at parts-per-trillion (ppt) levels, making them ideal for ultra-trace elemental analysis.
8: How accurate and reliable is the ICP Mass Spectrometer?
ICP Mass Spectrometer offers high accuracy and precision with minimal interference, especially when combined with internal standards and collision/reaction cell technology.
9: How long does an ICP Mass Spectrometer analysis take?
Typical analysis times range from a few seconds to a few minutes per sample, depending on the number of elements being measured and the method setup.