Spectrometer

Flame Photometer NFP-100
Flame Photometer NFP-100
Testing Elements K,Na
Display Value Optical power
No of Channels 2
Data Range 0000~9999
Get quote
Flame Photometer NFP-101
Flame Photometer NFP-101
Testing Elements K, Na
Display Concentration value
Element Display Channels Max. 3 channel
Data Range 0.000~999
Get quote
Flame Photometer NFP-102
Flame Photometer NFP-102
Testing Elements K, Na and Li
Display Value Concentration value
No of Channels 3
Data Range 0.000~999.9
Get quote
Flame Photometer NFP-103
Flame Photometer NFP-103
Testing Elements K, Na and Ca
Display Value Concentration value
No of Channels 3
Data Range 0.000~999.9
Get quote
Flame Photometer NFP-104
Flame Photometer NFP-104
Testing Elements K, Na and Ba
Display Value Concentration value
No of Channels 3
Data Range 0.000~999.9
Get quote
Flame Photometer NFP-105
Flame Photometer NFP-105
Testing Elements K, Li, Na, and Ca
Display Value Concentration value
No of Channels 4
Data Range 0.000~999.9
Get quote
Flame Photometer NFP-106
Flame Photometer NFP-106
Testing Elements K, Li, Na, Ca and Ba
Display Value Concentration value
No of Channels 5
Data Range 0.000~999.9
Get quote
Inductively Coupled Plasma Emission Spectrometer NICP-100
Inductively Coupled Plasma Emission Spectrometer NICP-100
Sampling time 100ms - 10s
Photomultiplier tube R212UH
Sampling System Specification: - Quartz tubes 20mm three concentric type
Nebulizer 6mm, coaxial type
Get quote
FTIR Spectrometer NIRS-100
FTIR Spectrometer NIRS-100
Wavenumber Range 7800 ~ 350 cm-1
Resolution 1 cm-1
Signal Noise Ratio 30000:1 (4cm-1; sample and background scan for 1 min 2100cm-1)
Detector Pyro electric detector
Get quote
Portable Mineral Spectrometer NPMS-100
Portable Mineral Spectrometer NPMS-100
Method of Analysis Energy Dispersive X Ray Fluorescence method
Elements measuring range Elements ranging atomic number 12 to 92 few namely,Ti,V,Cr,Mn,Fe,Co,Ni,Cu,Zn,Ga,Ge,Zr,Nb,Mo,Ru,Rh,Ag,In,Sn,Sb,Hf,Ta,W,Re,Pt,Au,Pb,Bi,Mg,Al,P,S and etc.
Content range ppm ~ 99.99%
Detection time 1-60 seconds
Get quote
Hand-Held XRF Analyzer NPXRF-101
Hand-Held XRF Analyzer NPXRF-101
Analytical Method Energy-dispersive X-ray fluorescence analytical method
Elements Measuring Range Atomic numbers from 12 to 92[elements from magnesium (Mg) to uranium(U)] can be measured
Simultaneous Detector Elements Simultaneous analysis of 40 elements
Microcomputer System Customized system; CPU: 1G, System memory: 1G, Extended stored maximum support: 32G, Standard: 4G for mass storage data
Get quote
Raman Spectrometer NRS-100
Raman Spectrometer NRS-100
Excitation wavelength 785 nm
Spectral resolution 4 cm-1
Spectral range 250-2700, 200-3500, and 200-4300 cm-1
Maximum laser output 500mW
Get quote
Raman Spectrometer NRS-200
Raman Spectrometer NRS-200
Wavelength range 200~800 nm
Wavelength accuracy ≤ 0.4 nm
Wavelength repeatability ≤ 0.2 nm
Stray light ≤ 10-3
Get quote
Energy Dispersive XRF Spectrometer NXRF-100
Energy Dispersive XRF Spectrometer NXRF-100
Detection method Energy dispersion X-Ray fluorescence
Accuracy ±0.01%
Machine resolution 129 ± 5eV
Measuring range 1% - 99.999%
Get quote