Any Query ?
Horizontal Autoclave NHA-104
Horizontal Autoclave NHA-104 is a cyclindrical, horizontal pressure steam sterilizer with an automatic pressure-temperature controller. These front-loading autoclaves combine of high temperature and pressure to bring about decontamination and sterilization of biological waste, culture media, instruments and lab ware. The whole body is a highly durable stainless steel with an installed electric heater for more efficient steam production and advanced vacuum for enhanced drying of discarded material. It is user-friendly and play important role in sterilization procedures across various Hospitals, Pharmaceutical companies, Biopharma and Microbiology laboratories etc.
Capacity | 500 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 700 × 1300 mm |
Working Pressure | 0.22 Mpa |
Working Temperature | 134°C |
Heat Fluctuation | ≤ ± 1°C |
Time for sterilization | 0 - 60 min |
Time for drying | 0 - 60 min |
Adjustable temperature range | 105°C - 134°C |
Power | 18 kW/ AC220V, 50Hz |
Overall Dimension | 1800 × 900 × 1820 mm |
Packing Dimension | 1850 × 1050 × 2100 mm |
Net Weight | 470 kg |
Gross Weight | 580 kg |
Employed for sterilization in microbiological, pharmaceutical, clinical and hospital labs.
Accessories No | Name |
1 | Pressure gauge |
2 | Water level controller |
3 | Heating element |
4 | Wire baskets |
5 | Silicon gasket for the lid |
6 | Soft tube |
6 | Spanner |
6 | Power cord |
Capacity | 20 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 250 × 420 mm |
Capacity | 24 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 250 × 520 mm |
Capacity | 35 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 300 × 500 mm |
Capacity | 50 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 340 × 550 mm |
Capacity | 45L |
Working Temperature | 134℃ |
Working Pressure | 0.22 Mpa |
Maximum Temperature | 139℃ |
Capacity | 35 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 318 × 450 mm |
Capacity | 75 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 400 × 600mm |
Capacity | 100 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 440 × 650mm |
Capacity | 120 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 480 × 660mm |
Capacity | 150 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 510 × 740mm |
Capacity | 50 L |
Chamber Dimension | Φ 340 × 550 mm |
Working Pressure | 0.23MPa |
Designed Pressure | 0.28Mpa |
Capacity | 18 L |
Chamber Volume | ∮ 280 × 260 mm |
Working Pressure | 0.14 - 0.16 Mpa |
Working Temperature | 126 °C |
Capacity | 24 L |
Chamber Volume | ∮ 280 × 390 mm |
Working Pressure | 0.14 - 0.16 Mpa |
Working Temperature | 126 °C |
Chamber volume | 6 L |
Sterilization temperature | 115 ℃ to 135 ℃ (Selectable) |
Ambient temperature | 5 to 40 ℃ |
Working pressure | 42 kPa to 212 kPa |
Capacity | 250 L |
Working Pressure | 0.00 to 3.50 bar |
Working Temperature | 100℃ to 135℃ |
Holding Time | 05 min to 30 min |