Gas Chromatography NGC-101

Gas Chromatography NGC-101

Gas Chromatography NGC-101

Gas Chromatography NGC-101 is a high-performance system with an advanced microcomputer-based temperature control system. Designed with a column oven, a data acquisition system, real-time instrument monitoring system, detection signal acquisition, PC control, 2 independent analogue signal outputs, flexible sample injection and M6 software. The oven supports quick heat-up and rapid cool-down with an automatic back door opening and can hold up to 3 chromatographic columns.

Specifications
Sample Introduction System Sample Injector and Evaporation Chamber
Control System Flow rate 200 ml/min (N2), 1000 ml/min (He)
Flow rate accuracy ± 5%
Flow rate repeatability ± 0.35%
Control System Split ratio 0 to 5000 (He), 0 to 1000 (lM2)
Control System Inlet temperature 0 to 420 °C
Column Oven Temperature Range Ambient Temperature +7 °C to 400 °C (In 1 °C increment)
Column Oven Temperature Accuracy ± 0.02 °C
Column Oven Cooling Time 400 °C to 50 °C In 8 to 10 min at 25 °C ambient
Programmed Temperature Setting 0.1 °C to 40 °C/min (In 1°C increment)
Program Ramps 7 Ramps in Total (10 Ramps Available with Control Workstation)
Flame Ionization Detector (FID) Detection Limit ≤ 3 × 10-12 g/s (C16)
FID Test Result ≤ 3 × 10-12 g/s (C16)
FID Drift ≤ 6 × 10-13 A/30 Min
FID Noise ≤ 5 × 10-14 A
FID Linearity Range ≥ 106
Thermal Conductivity Detector (TCD) Sensitivity ≥ 5000 mV, ml/mg (C16)
TCD Baseline Noise ≤ 20 µV
TCD Drift ≤ 60 µV/h
TCD Linearity Range ≥ 104
Flame Photometric Detector (FPD) Detection Limit ≤ 8 × 10-13 g/s (P); ≤ 8 × 10-11 g/s (S)
FPD Drift ≤ 2 × 10-11 A/30 Min
FPD Baseline Noise ≤ 5 × 10-12 A
Nitrogen-Phosphorus Detector (NPD) Detection Limit ≤ 5 × 10-12 g/s (N) (Azobenzene)
≤ 5 × 10-13 g/s (P) (Malathion)
Electron Capture Detector (ECD) Linear range ≥ 103 (y -666)
ECD Baseline drift ≤ 80 µV/h
ECD Baseline Noise ≤ 80 µV
ECD Detection Limit ≤ 2 × 10-13 g/ml (y -666)
Internal Dimension (L × W × H) 284 × 280 × 241 mm
External Dimension (L × W × H) 340 × 345 × 281mm
Features
Applications

Gas chromatography is used for separation and detection of thermally stable chemical compounds mainly in areas like environmental monitoring, food and technology, pharmaceutical drug testing, forensic department, biological analysis, geochemical research and clinical research.

Standard Accessories

Carrier Gas System: air source/ purification and desiccation device/ flow rate control device
Sample Introduction System: sample injector
Separation System: chromatographic column (packed column and capillary column)
Temperature Control System (Column Oven): constant temperature and programmed temperature
Detector: FID/ FPD/ NPD

Buy Now

GC


Gas Chromatography Mass Spectrometry NGMS-100

GC Inlet Temperature Maximum 450°C
GC Pressure Range 0 to 100 psi<br/> ± 0.002psi
GC Pressure Control Mode Electronic Pressure Control (EPC), Support CV and CC
GC Split Mode Split/Splitless, Max. Split Ratio, 1000:1