Gas Chromatography

Gas Chromatography Mass spectrometry NGMS-100
For GC
Inlet temperature Max. 450°C
Pressure range 0 to 100psi, ±0.002psi
Pressure control mode Electronic pressure control (EPC), support CV and CC
Split mode Split/splitless, max. split ratio: 1000:1
Column oven working temperature Room temperature+4°C to 450°C
Heating rate Up to 120°C/min
Temperature programming 7 stages/ 8 platforms
Auto Sampler Optional
For MS
EI source ionization energy 5W to 250,V (Adjustable)
Mass range 1.5~1000 amu
Resolution Unit resolution (full width at half maximum)
Ion source temperature 100 to 3500
Filament emission current 0-350 pA
GC-MS Interface temperature Max. 450°C
Stability ±0.10 amu/48 hrs
Sensitivity Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS)
Scan rate Up to l000 amu/s
Vacuum Turbo molecular pump(67L/s)
Detector High energy dynode electron multiplier
Get quote
Gas Chromatography NGC-100
Display EPC (electronic pneumatic control) 7-inch touch screen display
Sample Introduction System sample injector and evaporation chamber
Column Oven
Temperature range Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
Temperature accuracy ± 0.02℃
Cooling time 350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting 0.1℃~80℃/min (in 1℃ increment)
Program ramps 20 ramps in total (99 ramps available with control workstation)
Size (L × W × H) 284 × 280 × 241mm (inside), 340 × 345 × 281mm (outside)
Flame Ionization Detector (FID)
Detection limit ≤8×10-12(n-hexadecane)
Drift ≤1.5×10-13A/h
Noise ≤3×10-14A/h
Linearity range ≥106
Get quote
Gas Chromatography NGC-101
Sample Introduction System Sample Injector and Evaporation Chamber
Electronic Pneumatics Control System
Flow rate 200 ml/min (N2), 1000 ml/min (He)
Flow rate accuracy ± 5%
Flow rate repeatability ± 0.35%
Split ratio 0 to 5000 (He), 0 to 1000 (lM2)
Inlet temperature 0 to 420 °C
Column Oven
Temperature Range Ambient Temperature +7 °C to 400 °C (In 1 °C increment)
Temperature Accuracy ± 0.02 °C
Cooling Time 400 °C to 50 °C In 8 to 10 min at 25 °C ambient
Programmed Temperature Setting 0.1 °C to 40 °C/min (In 1°C increment)
Program Ramps 7 Ramps in Total (10 Ramps Available with Control Workstation)
Size (L × W × H) 284 × 280 × 241mm (Inside); 340 × 345 × 281mm (Outside)
Flame Ionization Detector (FID)
Detection Limit ≤ 3 × 10-12 g/s (C16)
Best Test Result ≤ 3 × 10-12 g/s (C16)
Drift ≤ 6 × 10-13 A/30 Min
Noise ≤ 5 × 10-14 A
Linearity Range ≥ 106
Get quote