Gas Chromatography
COMPARE
Gas Chromatography NGC-100
Display
EPC (electronic pneumatic control) 7-inch touch screen display
Sample Introduction System
sample injector and evaporation chamber
Column Oven
Temperature range
Ambient temperature +7℃ ~ 420℃ (in 1℃ increment)
Temperature accuracy
± 0.02℃
Cooling time
350℃~100℃≤3min, 400℃~50℃ in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1℃~80℃/min (in 1℃ increment)
Program ramps
20 ramps in total (99 ramps available with control workstation)
Size (L × W × H)
284 × 280 × 241mm (inside), 340 × 345 × 281mm (outside)
Flame Ionization Detector (FID)
Detection limit
≤8×10
-12
(n-hexadecane)
Drift
≤1.5×10
-13
A/h
Noise
≤3×10
-14
A/h
Linearity range
≥10
6
Get quote
Compare
Gas Chromatography NGC-101
Sample Introduction System
Sample Injector and Evaporation Chamber
Column Oven
Temperature range
Ambient temperature +7℃ to 400℃(in 1°C increment)
Temperature accuracy
± 0.02°C
Cooling time
350℃ to 100℃ ≤3 min, 400°C to 50°C in 8-10 min at 25℃ ambient
Programmed temperature setting
0.1°C to 80°C/min (in 1°C increment)
Program ramps
20 ramps in total (99 ramps available with control workstation)
External Size (L × W × H)
340 × 345 ×281 mm
Internal Size
284 × 280 ×241 mm
Flame ionization detector (FID)
Detection limit
≤8×10-12g/s(n-hexadecane)
Drift
≤1.5×1013 A/h
Noise
≤3×10 -14 A
Linearity range
≥106
Thermal Conductivity Detector(TCD)
Maximum Temperature
400 ℃
Temperature control accuracy
±0.1℃
Sensitivity
≥10000 mV, mL/mg (n-hexadecane)
Drift
≤100 µV/30 min (after the instrument is stable for 2 hours)
Baseline noise
≤20 µ V
Linearity range
≥104
Get quote
Compare
Gas Chromatography Mass Spectrometry NGMS-100
For GC
Inlet temperature
Max. 450°C
Pressure range
0 to 100psi, ±0.002psi
Pressure control mode
Electronic pressure control (EPC), support CV and CC
Split mode
Split/splitless, max. split ratio: 1000:1
Column oven working temperature
Room temperature+4°C to 450°C
Heating rate
Up to 120°C/min
Temperature programming
7 stages/ 8 platforms
Auto Sampler
Optional
For MS
EI source ionization energy
5W to 250,V (Adjustable)
Mass range
1.5~1000 amu
Resolution
Unit resolution (full width at half maximum)
Ion source temperature
100 to 3500
Filament emission current
0-350 pA
GC-MS Interface temperature
Max. 450°C
Stability
±0.10 amu/48 hrs
Sensitivity
Full scan, 1 pg OFN at m/z 272 with S/N ≥30:1 (RMS)
Scan rate
Up to l000 amu/s
Vacuum
Turbo molecular pump(67L/s)
Detector
High energy dynode electron multiplier
Get quote
Compare
Hello
×
Suggested Products
Gas Chromatography NGC-101
IR Carbon and Sulphur Analyzer NCSA-104
Fully Automatic Chemistry Analyzer NFAC-200
Semi-automatic chemistry analyzers NSCA-100
Multitest analyzer NMTA-100
Multi gas analyzer NMA-270
Soil Moisture Meter NSMM-100
Differential Thermal Analyzer NDTA-100
Automatic melting point meter NMPM-100
Microbial Air Sampler NMAS-200
Viscometer NVM-101
Copyright ©2023 All rights reserved |