Labnics Differential Scanning Calorimeter NDSC-100 covers room temperature to 500 °C. Heating rate sets from 0.1 to 80 °C/min with 0.01 °C resolution. DSC range spans 0 to ±500 mW with 0.1 mW sensitivity. Nitrogen and oxygen switch automatically at up to 200 mL/min flow. This DSC calorimeter works as differential scanning calorimetry equipment for thermal analysis with programmable heating and constant temperature modes.


$7,925.00

Data Sheet

Specifications

Temperature Range Room temperature to 500 °C
Temperature Resolution 0.01 °C
Heating Rate 0.1 to 80 °C/min, freely set
DSC Range 0 to ±500 mW
DSC Resolution 0.01 mW
DSC Sensitivity 0.1 mW
Gas Atmosphere Control Nitrogen and oxygen, automatic switching
Gas Flow 0 to 200 mL/min
Temperature Control Mode Heating, constant temperature, programmable, continuous temperature
Temperature Probes Dual probes, with a sensor at the sample base for true sample temperature
Furnace Control PID control
Data Interface Computer connection
Display 7-inch touchscreen
Output Computer and printer
Power 300 W

Features

Dual Temperature Probes — Repeatable sample readings.

Automatic Gas Switching — Smooth nitrogen and oxygen changeover.

Compact Furnace — Freely adjustable heating rate.

Enclosed Bracket — Keeps furnace clean of contamination

Applications

Polymer Laboratories

Performance Testing Laboratories

Quality Control Laboratories

Research and Development Laboratories

Supports polymer development by showing how materials respond to temperature changes.

Compares material performance across samples through measured heat flow and thermal behaviour.

Checks incoming and finished samples against set thermal profiles to confirm consistent quality.

Gives development teams thermal data on glass transition, melting and crystallization of new materials.

Ask Expert

Related Models Of Differential Scanning Calorimeter

Labnics Differential Scanning Calorimeter range delivers maximum temperatures from 500 °C to 600 °C with heating rates up to 100 °C/min. Heat flow range runs from ±500 mW up to ±2000 mW, and temperature resolution goes down to 0.001 °C. Nitrogen and oxygen atmospheres run at flow up to 200 mL/min with automatic gas switching. PID furnace control and independent temperature sensing keep sample readings steady.