NDSC-100
Room temperature to 500 ℃ (Room temperature to 800 ℃ Optional) Temperature range
0.01℃ Temperature resolution
0.1 ~ 80 ℃ / min arbitrary set Heating rate
Differential Scanning Calorimeter NDSC-100
Labnics Product Data Sheet · Laboratory Equipment
Differential Scanning Calorimeter

Differential Scanning Calorimeter NDSC-100

Differential Scanning Calorimeter NDSC-100 has a temperature resolution of 0.01 °C and can identify the inner heat transition related to temperature and heat flow. Designed with touch screen display for setting the several parameters like temperature, sample temperature, oxygen and nitrogen flow rate and thermal signals. It has double temperature probe to ensure repeatability of the sample temperature measurements. Equipped with USB communication interface for reliable transfer of the data.

Key metrics
Room temperature to 500 ℃ (Room temperature to 800 ℃ Optional)
Temperature range
0.01℃
Temperature resolution
0.1 ~ 80 ℃ / min arbitrary set
Heating rate
Differential Scanning Calorimeter NDSC-100
Labnics Ltd.

Specifications

Temperature range Room temperature to 500 ℃ (Room temperature to 800 ℃ Optional)
Temperature resolution 0.01℃
Heating rate 0.1 ~ 80 ℃ / min arbitrary set
Constant temperature advise Advise < 24 hours
Temperature control mode Heating, constant temperature, programmable, temperature continuous
DSC range 0 to ± 500 mW
DSC resolution 0.001 mW
DSC accuracy 0.001 mW
Atmosphere control of gas Nitrogen, oxygen (automatic switching)
Gas flow 0-200 ml/min
Gas pressure 0.2 M Pa
Crucible Aluminum crucible, Φ 6.6 × 3 mm
Standard substances (indium, tin, zinc), the user can correct temperature and heat enthalpy
Data interface Standard USB interface
Display mode 24 bit color, 7 inch touch screen display
Output way Computer and printer
Power supply AC110V/220V, 50/60Hz, Single Phrase
Power 300W
Differential Scanning Calorimeter NDSC-100 · Product Details

Features

  • Large touchscreen to display temperature and flow rate of gases
  • USB Communication interface for transfer of data and is able to restore the connection
  • Compact furnace structure and arbitrary adjustable heating rate
  • Streamlined installation procedure for better user experience
  • Temperature sensor installed on the furnace wall
  • PID Control for controlling the furnace temperature
  • Double temperature probe to ensure reproducible results of the sample temperature measurements
  • Fast and steady atmospheric flow with auto switch
  • Temperature and heat content can be adjusted according to the requirements of the user
  • Provides heating and constant temperature scanning
  • Fully enclosed bracket structure design prevents articles falling into the furnace body, polluting the furnace body and reducing maintenance rate

Applications

Differential Scanning Calorimeter is extensively used for polymer development, performance testing & quality control in the pharmaceutical industries, research labs and academic institutions.
Laboratory equipment · Designed for precision
Labnics
Better instruments.
Better laboratories.
Start a conversation

Let’s build your next laboratory.

Explore dependable laboratory equipment and expert support for research, testing and quality-control environments.

Head OfficeUnit 2D Station House, 1 Pembroke Broadway, Camberley, Surrey GU15 3XD, United Kingdom.
Labnics © 2026. All Rights Reserved.
0