Let's Chat

Any Query ?

Brookfield Viscometer NVM-702

Brookfield Viscometer NVM-702

Brookfield Viscometer NVM-702

Brookfield viscometer NVM-702 adopted with advanced micro-processor based technology, controls speed, test operations, data collection and interpretation. With 25 mPa.s to 1×10000000 mPa.s measurement range, it provides fast, accurate, reliable results. Equipped with white backlight LCD display enables user to view viscosity test parameters like No. of samples, rotors specification, speed etc.

Specifications
Measurement range 25 mPa.s to 1×10000000 mPa.s
Rotors Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles)
Rotor speed (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min
Temperature control range 45 to 200°C
Temperature control accuracy ± 0.1°C
Sample cylinder 20 ml
Measurement mode Automatic
Print output Needle printer
Connection to PC RS232 interface
Power supply AC 220V ± 10%, 50 Hz
Relative humidity ≤ 80%
Ambient temperature 5 to 35°C
Dimension 460 × 410 × 450 mm
Gross weight 14 kg
Features
Applications

Brookfield Viscometer has applications in paint & oil industry, pharmaceuticals, food & beverage industry.

Optional Accessories

Accessories No Name
1 Rotor no. 30
2 Water bath

Buy Now

Brookfield Viscometer


Kinematic Viscometer NKV-100

Temperature control range Room temperature - 120°C
Temperature control precision ≤ ± 0.01°C
No. of liquid bath hole 4
Test times 1 to 6 time/times, adjustable

Kinematic Viscometer NKV-101

Temperature control range -40°C - 60°C
Temperature control precision ≤ ± 0.03°C
No. of liquid bath hole 2
Test times 2 to 6 time/times, adjustable
Kinematic Viscometer NKV-103
Temperature control range RT to 150℃
Temperature setting 20℃, 40℃, 50℃, 80℃, 100℃, any value (higher than room temperature to 150℃)
Temperature control accuracy ± 0.1℃
Timing range 0 to 999s
Kinematic Viscometer NKV-104
Temperature range Ambient to 100.0℃
Temperature control accuracy ±0.01℃
Bath capacity 20L
Timing range 0.0s to 9999.9s

Kinematic Viscometer NKV-105

Temperature control range Room temperature to 100°C
Measuring range Kinematic viscosity: 0.5 to 20000mm²/s<br/> Dynamic viscosity: 0. 3 to 40000mPa.s
Temperature control accuracy 0.01℃
Ambient temperature 15 to 35°C

Kinematic Viscometer NKV-106

Measuring parameters Kinematic Viscosity, Dynamic Viscosity, Density, Viscosity Index
Measuring Viscosity Range 0.2 to 30,000 mm²/s
Measuring Density Range 0 to 3 g/cm³
Temperature Range -60℃ to 140℃

Rotational Viscometer NVM-101
Measuring range 0.1 to 2,000,000 mPa.s
Rotating speed 0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%
Rotational Viscometer NVM-500
Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%

Rotational Viscometer NVM-501

Measuring range 1 to 100000 mPa.s
Rotating speed 3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±0.5%

Rotational Viscometer NVM-502

Measuring range 1 to 200000 mPa.s
Rotating speed 0.3/0.6/1.5/3.6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%

Rotational Viscometer NVM-503

Measuring range 1 to 600000 mPa.s
Rotating speed 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min)
Rotor 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar
Measuring Error (Newtonian liquid) ±1%

Automatic Kinematic Viscometer NAKV-100
Temperature control range Room temperature + 5 ℃ to 100 ℃
Temperature control accuracy ± 0.01 ℃
Time accuracy ± 0.01% (not greater than ± 0.01% for 60 minutes)
Viscosity range 0.3 to 5000 mm²/s

Kinematic Viscometers NKV-102

Temperature Range -70℃ to 135℃.
Accuracy ±0.1℃
Ambient Temperature 5℃ to 40℃;
Ambient Humidity <85%

Automatic Kinematic Viscometer NAKV-101

Temperature control range Room temperature to 120 °C can be adjusted
Temperature control accuracy ± 0.05 ° C
Ambient temperature 5 to 40 ° C
Ambient Humidity < 85%RH