| Door opening method |
Top-opening door |
| Capacity |
83 liters |
| Internal usable height |
340 mm |
| Maximum loading capacity |
2000ml×4 1000ml×8 500ml×12 250ml×18 100ml×32 50ml×45 Microplate×12 |
| Temperature range |
4 to 60°C (Ambient temp-18°C, minimum- 4°C) |
| Temperature accuracy |
±0.1°C |
| Temperature uniformity |
≤±1.0°C at 37°C |
| Ambient temperature range |
5 to 35°C |
| Temperature editing |
Repeat/Pace/8-segment curve editing |
| Rotation way |
Rotary/ reciprocating switchable |
| Rotation speed |
20 to 800 rpm (1200rpm) |
| Rotation accuracy |
±1 rpm |
| Throw |
3mm (1.5mm) |
| Timing range |
0 to 999.59H |
| Display |
LCD |
| Control |
P.I.D microcomputer |
| Circulation |
Forced circulation convection |
| Drive mode |
Single-axis balanced drive |
| Tray material/Flask clamp/Chamber material |
Stainless steel type 304 |
| Decontamination method |
UV sterilization |
| Bearings |
Original imported double row bearings |
| Compressor |
Variable frequency compressor |
| Clamp types |
Shake flask, spring, test tube rack, sticky plate, ELISA plate |
| Heating power |
400W |
| Cooling power |
150W |
| Motor power |
150W |
| Power supply |
220V±10%, 50/60Hz |
| Tray size |
420×400mm |
| Internal dimension |
490×470×360mm |
| External dimension |
778×685×600mm |
| Net weight |
83 kg |
FAQ for Benchtop Incubator Shaker NBIS-505
1: Can the Benchtop Incubator Shaker NBIS-505 handle different types of laboratory vessels?
Yes, our Benchtop Incubator Shaker supports a wide variety of clamps such as shake flasks, test tube racks, sticky plates, and ELISA plates. This versatility allows me to perform different types of experiments using the same equipment.
2: How does the Benchtop Incubator Shaker NBIS-505 maintain uniform conditions inside the chamber?
Our Benchtop Incubator Shaker uses a forced air circulation system along with a three-dimensional airflow design that eliminates hot or cold spots. This ensures all my samples are exposed to the same growth environment for consistent results.
3: What features make the Benchtop Incubator Shaker NBIS-505 energy-efficient and durable?
The Benchtop Incubator Shaker comes with a variable frequency compressor that ensures efficient cooling with reduced energy consumption. Its stainless steel 304 chamber, double-row bearings, and molded ductile iron components make it long-lasting and reliable.
4: What happens if the door is opened during operation?
The Benchtop Incubator Shaker automatically stops when the door is opened. This safety feature prevents accidents, protects my samples, and ensures smooth operation when resumed.
5: Can the Benchtop Incubator Shaker be used for long experiments?
Yes, our Benchtop Incubator Shaker has a wide timing range of up to 999.59 hours, allowing me to run both short-term and long-term experiments. This feature is particularly useful for extended incubation or culture growth studies.