Any Query ?
Atomic Absorption Spectrophotometer NAAS-200
Atomic Absorption Spectrophotometer NAAS-200 is an analytical instrument that helps in the quantification of trace metal elements on their basis of spectral activity in gaseous states of the test under study. It is a microprocessor-controlled system with an RS232 interface that effectively controls fuel gas of burner and automatic positioning and optimization of each 8 hollow cathode lamp turret. It is equipped with an advanced flame atomizer with rapid heating and analysis of a sample that retains the accuracy of the instrument. The audible sound alarm system effectively monitors flame conditions and ensures the safety of instruments as well as of the user.
Wavelength Range | 190nm - 900nm |
Grating Groove | 1800/mm |
Spectral Bandwidth | 0.1nm/0.2nm/0.5nm/1.0nm/2.0nm |
Wavelength Accuracy | ≤ 0.15nm |
Wavelength Reproducibility | ± 0.1nm |
Wavelength Resolution | 0.2nm ± 0.02nm |
Baseline Stability | ≤ ± 0.002A/30 minutes( static) ; ≤ ± 0.005A/30 minutes.(dynamic) |
Background Correction | Deuterium Arc 1.0Abs Self Reversal 1.0Abs |
Light Source | 3 position automatic turret,automatic alignment lamp |
Flame Atomizer Specifications: Cu concentration | 0.015μg/mL/1%. |
Detection limits (Cu): | 0.002μg/mL |
Precision | RSD ≤ 0.5% |
Relative Humidity | 20-80% |
Ambient temperature | 15℃-35℃ |
Power Supply | 220V (5%~-10%), 50/60 Hz; 5000VA |
Dimensions (L×D×H) | 1270 × 640 × 730 mm |
Weight | 120 kg |
It has multidisciplinary applications in field of science for quantitative and qualitative analysis for test samples like blood, serum, food samples, petrochemical etc. It is commonly used in field of food, agriculture, geology, Clinical, Environmental, Mining and Pharmaceutical etc.
Accessories No | Name |
1 | 3 lamps (Cu,Mg,Fe) |
2 | PC software |
3 | Atomizer x 2 |
4 | 1.5A/3A fuse x 2 |
5 | USB line |
6 | Acetylene hose clip x 3 |
7 | 3 meter acetylene gas pipe |
Accessories No | Name |
1 | Acid proof atomizers |
2 | Hydride generator |
3 | AAS Flame autosampler |
4 | Graphite furnace autosampler |
Wavelength range | 200~900nm |
Excitation/emission Accuracy | ±1nm |
Wavelength Repeatability | ≤0.5nm |
Excitation/emission bandwidth | 2nm, 5nm, 10nm, 20nm |
Detector | 2048-element linear silicide CCD array |
Light source | Long-life pulsed xenon flash lamp |
Wavelength range | 200 ~ 850nm |
Wavelength accuracy | ± 1nm |
Detector | 3864 linear CCD array |
Light source | Long-life pulsed xenon flash lamp |
Wavelength range | 190-850nm |
Wavelength accuracy | ±1nm |
Detector | 2048-element linear silicide CCD array |
Light source | Long-life pulsed xenon flash lamp |
Wavelength range | 200 ~ 850nm |
Wavelength accuracy | ± 1nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 2.0/4.0nm |
Wavelength Accuracy | ± 1.0nm |
Wavelength Repeatability | ≤ 0.3nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 2.0nm |
Wavelength Accuracy | ± 0.8nm |
Wavelength Repeatability | ≤ 0.3nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 1.8nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 2.0/4.0nm |
Wavelength Accuracy | ±0.8nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 2.0nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 1.8nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 1.0nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 0.5/1.0/2.0/4.0/5.0 nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 2.0nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 1.8nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 1.0nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 190~1100nm |
Spectral Bandwidth | 0.5/1.0/2.0/4.0/5.0nm |
Wavelength Accuracy | ± 0.3nm |
Wavelength Repeatability | ≤ 0.2nm |
Wavelength Range | 325~1020nm |
Spectral Bandwidth | 4.0nm |
Wavelength Accuracy | ± 2.0nm |
Wavelength Repeatability | ≤ 1nm |
Wavelength Range | 320 ~ 1100nm |
Spectral Bandwidth | 4.0 /2.0 nm |
Wavelength Accuracy | ± 1.0nm |
Wavelength Repeatability | ≤ 0.3nm |
Wavelength Range | 320 ~ 1100nm |
Spectral Bandwidth | 2.0 nm |
Wavelength Accuracy | ±0.8nm |
Wavelength Repeatability | ≤ 0.3nm |
Wavelength Range | 320 ~ 1100nm |
Spectral Bandwidth | 1.8nm |
Wavelength Accuracy | ±0.5nm |
Wavelength Repeatability | ≤ 0.2nm |
Caliber | Switchable Caliber 4mm and 8mm |
SCI /SCE | SCI and SCE |
Light type | High accuracy full spectrum LED+Dual UV |
Fix position | Camera location |
Wavelength Range | 900 nm to 2500 nm |
Wavelength Accuracy | ≤ 0.2 nm |
Wavelength Reproducibility | ≤ 0.05 nm |
Spectral bandwidth | 8 nm |
Labnics Automatic UV-Visible Spectrophotometer provides measurement of absorbance and transmittance across the UV and visible light spectrum ranging from 190 nm to 1100 nm. They utilize advanced optics and high-resolution detectors for accurate, reproducible results across various samples. This ensures accurate results for different types of samples, including liquids and solids. Equipped with automated sample handling systems, they facilitate high-throughput analysis. Our Spectrophotometer incorporates connectivity options for data transfer making it an essential tool for research and quality control in pharmaceutical, environmental, and food industries.
Wavelength Range | 190 to 1100nm |
Spectral Bandwidth | 2nm |
Wavelength Accuracy | Full wavelength 0.3nm (656.1nm 0.1nm) |
Wavelength Repeatability | 0.1nm |