WhatsApp
Organic Element Analyzer NOEA-102

Organic Element Analyzer NOEA-102

Organic Element Analyzer NOEA-102 offers a 0.002 to 20 mg measuring capacity for carbon, hydrogen, nitrogen, sulfur, and oxygen detection. This analyzer accommodates both micro and macro sample sizes using high-temperature oxidation. It ensures thorough sample decomposition and supports accurate quantification of resulting gases. This system features stable operation with high-resolution detection. Our analyzer is designed with manual and automatic sample handling for efficient analysis.


$125,000.00

Data Sheet

Specifications

Measuring Range Carbon: 0.002 to 20 mg
Hydrogen: 0.002 to 5 mg
Nitrogen: 0.002 to 20 mg
Sulfur: 0.002 to 6 mg
Oxygen: 0.002 to 2 mg
Accuracy <0.2% (certified standard; purity >99.9%)
Precision <0.1% (certified standard; purity >99.9%)
Sampler Pneumatic autosampler / Electronic autosampler / Manual sampler
Gas Requirements Oil-free compressed air
Power Supply 230V, 50/60Hz, 5A, 1100W
Dimensions (L×W×H) 81 × 50 × 37 cm
Weight 68 kg

Features

  • Modular combustion chamber
  • Automated gas separation
  • Precision flow control
  • Multi-sample loading system
  • Advanced safety monitoring

Applications

Organic Element Analyzer NOEA-102 delivers precise CHNSO quantification for high-accuracy elemental profiling. It is ideal for use in chemical, environmental, and academic research laboratories requiring multi-element analysis.

Optional Accessories

Automatic sampler 98 holes × 1 

Automatic sampler 147 holes × 1

Optional Consumables

500 O Analysis Consumables Kit × 1

1000 CHNS Analysis Consumables Kit × 1

Ask Expert

FAQ for Organic Element Analyzer NOEA-102

1: How does Organic Element Analyzer NOEA-102 manage combustion temperature across elements?

Labnics Organic Element Analyzer includes dual-zoned furnaces with separate thermal control for combustion and separation. The system prevents interference between stages. Uniform heating ensures consistent oxidation. This enhances signal clarity and test stability.

2: Can Organic Element Analyzer NOEA-102 detect oxygen without interfering with CHNS readings?

Yes, Organic Element Analyzer uses dedicated pathways and timed detection for oxygen quantification. It separates signals using precise gas routing. Chromatographic channels reduce overlap between elements. The result is independent and interference-free reporting.

3: How does Organic Element Analyzer NOEA-102 support multi-sample flexibility during extended runs?

Our analyzer includes automatic loading and queue-based scheduling. It allows users to switch between formats without recalibration. Built-in diagnostics track sample status and internal temperature. This reduces delays across sequential tests.

4: What safety mechanisms are built into Labnics Organic Element Analyzer NOEA-102?

Labnics Organic Element Analyzer features flow detection, overheat shutdown, and leak alerts. Software indicators prompt corrective actions. Gas input is regulated to avoid sudden surges. These features keep operations secure under all conditions.

5: Can Organic Element Analyzer NOEA-102 be operated continuously without resetting calibration?

Yes, Organic Element Analyzer uses long-term calibration retention for repeat use. Internal memory stores test parameters. Users can resume sequences without recalibrating. This supports uninterrupted workflows for high-volume testing.

6: How do Organic Element Analyzers maintain long-term detection accuracy?

Labnics Organic Element Analyzers use drift-free thermal sensors with regulated combustion chambers to minimize variation. These components deliver stable readings across multiple runs and reduce recalibration needs during long-term use.

7: What detection methods are used in Organic Element Analyzers?

Yes, Organic Element Analyzers operate on thermal conductivity or gas chromatography principles to evaluate CHNS content. These detection methods provide clear resolution across various sample types and maintain high analytical precision.

8: How do Organic Element Analyzers manage different sample types?

Our Organic Element Analyzers process solids, powders, and semi-solids without extensive preparation. Integrated loading units and heat-stable containers allow uniform sample handling throughout analysis cycles.

9: How is operational data captured and exported in Organic Element Analyzers?

Organic Element Analyzers store results internally and support direct data transfer through USB or external output. This ensures reliable documentation, quick access to past records, and smooth integration with lab data systems.

Related Models Of Organic Element Analyzer

Organic Element Analyzers measure carbon, hydrogen, nitrogen, and sulfur in various materials. These systems use thermal conductivity or gas chromatography with high-temperature combustion. They support powders, solids, and particulates while maintaining repeatable detection across all formats. These analyzers perform CHNS evaluation through user-defined programmable cycles. Our analyzers feature built-in filtration units and automated samplers for smooth operation.

Labnics © 2026. All Rights Reserved.
0