Any Query ?
Vacuum Autoclave NVAC-100
Vacuum Autoclave NVAC-100 can accommodate a large volume capacity of 250L. Our autoclave offers precise working temperatures ranging from 100℃ to 135℃ and pressure regulation of 0.00 to 3.50 bar. Utilizes vacuum method and employs saturated steam for sterilization. Equipped with safety measures such as dual doors that ensure safe operation with pressure and temperature interlocks. Offers diverse sterilization options, including tests and customization for better use.
Capacity | 250 L |
Working Pressure | 0.00 to 3.50 bar |
Working Temperature | 100℃ to 135℃ |
Holding Time | 05 min to 30 min |
Time for Sterilization | 180 min |
Adjustable Temperature Range | 0℃ to 138℃ |
Agar holding Temperature | 95℃ to 105℃ |
Temperature Uniformity | ±1℃ |
Warming Temperature | 45℃ to 60℃ |
Door Types | Single Door Automatic Sliding |
Loading Type | Front Loading |
Steam System |
Built-in Steam Generator Steam Injection System |
Water Supply | Automatic Pumping System |
Door Lock System | Magnetic Lock with Sensor |
Door Lock Temperature | At 70℃ |
Sensor |
Temperature Pressure Leak Steam |
Test Options |
Bowie-Dick (Vacuum-Leak) Test Pressure-Leak Test |
Cycle Options |
Liquid Cycle Solid cycle Porous (Fabric)Cycle |
Alarm | Visual and Acoustic Alarm for High Temperature and Pressure |
Power Supply | 380V, 50Hz |
Power Consumption | 2KW |
Internal Dimension | 1800× 900× 1300mm |
External Dimension | 1800 ×1150× 1300mm |
Weight | 850kg |
Vacuum autoclaves are utilized in research laboratories and pharmaceutical industries, serving to sterilize equipment. Through the removal of air and steam, they efficiently eradicate pathogens, guaranteeing the safety of medical instruments for surgical procedures and other clinical uses.
Capacity | 150 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 440 × 1000 mm |
Working Pressure | 0.22 Mpa |
Capacity | 200 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 515 × 1000 mm |
Working Pressure | 0.22 Mpa |
Capacity | 280 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 600 × 1000 mm |
Working Pressure | 0.22 Mpa |
Capacity | 400 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 700 × 1100 mm |
Working Pressure | 0.22 Mpa |
Capacity | 500 L |
Body | 304 Stainless Steel |
Chamber Volume | ∮ 700 × 1300 mm |
Working Pressure | 0.22 Mpa |
Capacity | 150 L |
Body | Stainless Steel |
Type | Pressure Steam Sterilization |
Chamber Volume | Φ 440 × 1000 mm |
Capacity | 20 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 250 × 420 mm |
Capacity | 24 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 250 × 520 mm |
Capacity | 35 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 300 × 500 mm |
Capacity | 50 L |
Body | 304 Stainless-steel |
Type | Front loading |
Chamber volume | ∮ 340 × 550 mm |
Capacity | 45L |
Working Temperature | 134℃ |
Working Pressure | 0.22 Mpa |
Maximum Temperature | 139℃ |
Capacity | 35 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 318 × 450 mm |
Capacity | 75 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 400 × 600mm |
Capacity | 100 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 440 × 650mm |
Capacity | 120 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 480 × 660mm |
Capacity | 150 L |
Body | 304 Stainless Steel |
Door | Wheel-type, Quick-open door |
Chamber Volume | ∮ 510 × 740mm |
Capacity | 50 L |
Chamber Dimension | Φ 340 × 550 mm |
Working Pressure | 0.23MPa |
Designed Pressure | 0.28Mpa |
Capacity | 18 L |
Chamber Volume | ∮ 280 × 260 mm |
Working Pressure | 0.14 - 0.16 Mpa |
Working Temperature | 126 °C |
Capacity | 24 L |
Chamber Volume | ∮ 280 × 390 mm |
Working Pressure | 0.14 - 0.16 Mpa |
Working Temperature | 126 °C |
Chamber volume | 6 L |
Sterilization temperature | 115 ℃ to 135 ℃ (Selectable) |
Ambient temperature | 5 to 40 ℃ |
Working pressure | 42 kPa to 212 kPa |