WhatsApp
PH Conductivity Meter NPCM-101

PH Conductivity Meter NPCM-101

PH Conductivity Meter NPCM-101 offers a pH measuring ranges from -2.00 to 19.99 pH for precise analysis. It offers automatic temperature compensation for accurate measurements across varying temperatures. Our meter accurately measures multiple parameters, including pH, mV, conductivity, TDS, salinity, resistivity, dissolved oxygen, and temperature. It includes an LCD display for clear and easy reading of measurement results.


Catalog

Specifications

pH Measuring Range - 2.00 to 19.99 pH
pH Resolution 0.1/0.01 pH
pH Accuracy Meter: ±0.01 pH; Overall: ±0.02 pH
Input Current ≤ 2×10⁻¹² A
Input Impedance ≥ 1×10¹² Ω
pH Stability ±0.01 pH/3h
Automatic Temperature Compensation Range 0 to 100°C
ORP Measuring Range -1999 mV to 0 to 1999 mV (Probe Optional)
ORP Resolution 1 mV
ORP Accuracy ±0.1% FS
Temperature Range 32 to 212°F (0 to 100°C)
Conductivity Measuring Range 0.00 to 19.99μS/cm
20.0 to 199.9μS/cm
200 to 1999μS/cm
2.00 to 19.99mS/cm
20.0 to 199.9mS/cm
TDS Measuring Range 0 to 100 g/L
Salinity Measuring Range 0 to 100 ppt
Resistivity Measuring Range 0 to 100 MΩ·cm
Conductivity Resolution 0.01/0.1/1μS/cm; 0.01/0.1 mS/cm
Conductivity Accuracy Meter: ±1.0% FS; Overall ±1.5% FS
Automatic Temperature Compensation Range for Conductivity 0 to 50°C
Electrode Constant 0.1/1/10 cm⁻¹
Benchmark Temperature 25°C, 20°C, and 18°C
Dissolved Oxygen Measuring Range 0 to 40.00 mg/L (ppm); 0 to 200.0%
Dissolved Oxygen Resolution 0.1/0.01 mg/L (ppm); 1/0.1%
Dissolved Oxygen Accuracy Meter: ±0.10 mg/L; Overall ±0.40 mg/L
Dissolved Oxygen Response Time ≤ 30s (25°C, 90% response)
Residual Current ≤ 0.1 mg/L
Automatic Temperature Compensation Range for Dissolved Oxygen 0 to 45°C
Automatic Salinity Compensation Range for Dissolved Oxygen 0 to 45 ppt
Barometric Pressure Range 66 to 200 kPa (manual)
Dissolved Oxygen Automatic Calibration Air saturated by water; water saturated by air
Dissolved Oxygen Electrode Type Polarogram type
Data Storage Capacity 400 groups
Stored Content Series number, measuring value, measuring unit, and temperature
IP Rating IP57 Dustproof and waterproof
Power Source Two AA batteries (1.5V × 2)
Dimensions of Carrying Case 360 × 270 × 76 mm
Dimensions of meter 65 × 120 × 31 mm
Weight of carrier case 1.6 Kg
Weight of meter 180 g

Features

  • Large data storage
  • Built-in microprocessor chip
  • Automatic calibration
  • Self-diagnosis function
  • Auto power-off setting

Applications

  • PH Conductivity Meter analyzes water quality to ensure compliance with environmental standards. It is commonly utilized in industries like mining, power generation, water treatment, and environmental protection.

Standard Accessories

  • Plastic pH/ATC Three-in-One Combination Electrode
    Plastic Conductivity Electrode
    DO Electrode
    pH Standard Buffer Solution (pH 4.00, pH 7.00, pH 10.01)
    1413 μS/cm Conductivity Standard Solution
    Membrane Cap (for DO Electrode)
    DO Electrode Inner Solution
    Cathode Polishing Paper
    Screwdriver
    Carrying Case

Ask Expert

Relative Models Of pH Conductivity Meter

Portable pH Conductivity Meter NPCM-100

pH Range 2.000~20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, selectable
Catalog

Portable PH Conductivity Meter NPCM-102

Measuring Parameters Conductivity, temperature
Measuring Conductivity Range 0.01 to 20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm
Measuring Conductivity Resolution 0.001, 0.01, 0.1, 1
Catalog

Portable pH Conductivity Meter NPCM-103

pH Range -2.00 to 20.00 pH
pH Resolution 0.1, 0.01 pH
pH Accuracy ±0.01 pH
Catalog

BOD Meter

BOD Meter NBOD-100

Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Catalog

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Catalog
BOD Meter NBOD-102
Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Catalog

COD Analyzer

COD analyzer NCA-100
High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Catalog

COD Digester

Benchtop COD Digester NBCD-100

Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Catalog

Benchtop COD Digester NBCD-101

Digestion capacity 16 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 150 mm / ф20mm × 150 mm
Catalog

Conductivity Controller Analyzer

Conductivity Controller Analyzer NCCA-100
Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Catalog

Conductivity Meter (Portable)

Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.

Portable Conductivity Meter NCM-100
Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Catalog

Portable Conductivity Meter NCM-200

Measurement Range 0 to 400 mS/cm
Resolution 0.001 μS/cm to 0.1 mS/cm
Indication Error ±0.5% F.S
Catalog

Portable Conductivity Meter NCM-201

Conductivity range 0.000 μS/cm to 500 mS/cm
Conductivity resolution 0.001 μS/cm minimum, various range selection
Conductivity accuracy ±1.0% FS
Catalog
Labnics © 2025. All Rights Reserved.