Low Temperature Plasma Sterilizer NLTPS-100

Low Temperature Plasma Sterilizer NLTPS-100

Low Temperature Plasma Sterilizer NLTPS-100

Low Temperature Plasma Sterilizer NLTPS-100 offers a 63L capacity, designed for efficient sterilization. It utilizes a cassette system for safe and precise H2O2 delivery. This sterilizer features two layers of aluminum alloy punching plates to maximize space utilization. It has a high-quality pressure sensor that accurately monitors chamber pressure during the process. Our unit includes a high and low temperature alarm system to ensure safe and reliable operation

Specifications
Capacity 63L
Type Cassette
Sterilization temperature 50°C ± 5℃
Sterilization agent 60% H2O2
Sterilization cycle Fast sterilization: ≤25 min
Standard sterilization: ≤35min
Enhanced sterilization: ≤55min
H2O2 filling method Cassette, 12 vials of H2O2/cassette
New cassette: Automatic delivery
Used cassette: Automatic ejection
Master controller PLC control
Display 7-inch LCD touchscreen
Loading method 2 layers of aluminum alloy punching plate loaded with sterile items
Test methods Biological monitoring of Bacillus subtilis and Bacillus stearothermophilus
Biological indicator cultivator Yes
Alarm system High & low temperature alarming system
Door Automatic vertical sliding door with anti-pinch function
Door number Single-door/Double-door
Power consumption 500W
Power supply 110/220V, 50/60Hz
Chamber dimension 600×350×300mm
External dimension 790×670×1510mm
Packaging dimension 910×750×1700mm
Gross weight 233kg
Features
Applications

Low Temperature Plasma Sterilizer NLTPS-100 is used to eliminate pathogens without high heat or chemicals. It is commonly used in hospitals, clinics, and dental offices to sterilize sensitive medical instruments.

Buy Now

Low Temperature Plasma Sterilizer

Labnics Low Temperature Plasma Sterilizers use ionized gas for safe and effective sterilization. They maintain precise thermal control to ensure consistent disinfection. These units include safety features such as pressure and temperature monitoring, leak detection, and automatic shut-off. They are fully automated, ensuring reliable sterilization with minimal human intervention. Our low temperature plasma sterilizers come with an LCD touchscreen display for easy and user-friendly operation.


Bacti Cinerator Sterilizer NBCS-100

Maximum central temperature 825℃±50℃
Low grade temperature 480℃
Warm-up time 20 minutes to maximum temperature
Sterilization time 5 to 7 seconds