Kinematic Viscometer NKV-100
Kinematic Viscometer NKV-100 is an analytical instrument that helps determine the kinematic viscosity i.e., it measures the internal friction force when the liquid flows under the action of gravity of liquid petroleum products. Equipped with PID-controller and imported sensor, it offers a wide temperature-control range and high temperature-control precision. This instrument is used for research, development and quality control practices without any user intervention.
Temperature control range | Room temperature - 120°C |
Temperature control precision | ≤ ± 0.01°C |
No. of liquid bath hole | 4 |
Test times | 1 to 6 time/times, adjustable |
Heating power | 1000 W |
Refrigerating power | N.A |
Power supply | AC 220V± 10V ; 50Hz |
Dimension (L × W × H) | 440 × 350 × 520 mm |
Weight | 14 kg |
Kinematic Viscometer finds major applications in chemical and material industry, cosmetics, petroleum industry, research institutes, for analysis of fluids.
Measurement range | 25 mPa.s to 1×10000000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min |
Temperature control range | 45 to 200°C |
Measurement range | 100 mPa.s to 200000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | 5, 10, 20, 50 r/min |
Temperature control range | Room temperature to 200°C |
Speed | 0.1 to 200 infinitely variable speed, a total of 2000 speed options |
Measuring Range | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Rotor 1 – 4</td> <td style=min-width:50px>10 to 6 M mPa. s</td> </tr> <tr> <td style=min-width:50px>ULR</td> <td style=min-width:50px>1 to 6 K</td> </tr> <tr> <td style=min-width:50px>Rotor 18</td> <td style=min-width:50px>1.5 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 25</td> <td style=min-width:50px>240 to 4.8 M</td> </tr> <tr> <td style=min-width:50px>Rotor 31</td> <td style=min-width:50px>15 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 34</td> <td style=min-width:50px>30 to 600 K</td> </tr> </table> |
Display Mode | 5-inch color touchscreen |
Rotor | L1 – L4 (Standard); Enhanced Ultra – low Viscosity adapter ULR (optional); Small sample adapters (rotors 18, 25, 31, 34) (optional) |
Measuring range | 0.1 to 2,000,000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±0.5% |
Measuring range | 1 to 200000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 600000 mPa.s |
Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Temperature control range | Room temperature + 5 ℃ to 100 ℃ |
Temperature control accuracy | ± 0.01 ℃ |
Time accuracy | ± 0.01% (not greater than ± 0.01% for 60 minutes) |
Viscosity range | 0.3 to 5000 mm²/s |
Temperature Range | -70℃ to 135℃. |
Accuracy | ±0.1℃ |
Ambient Temperature | 5℃ to 40℃; |
Ambient Humidity | <85% |