Industrial Infrared Thermometer NIIT-100
Industrial Infrared Thermometer NIIT-100 is a durable and accurate non-contact thermometer with wide measurement range, adjustable emissivity and quick response time. The temperature is determined by emitting infrared radiation on the exposed surface of the desired sample. With ergonomic design and backlit display, it is designed for highest level of performance making it suitable for wide range of industrial applications.
Optical resolution | 30:01 |
Measuring range | -50 °C to 750 °C |
Measuring accuracy | ± 2°C |
Response time | 500 ms |
Emissivity | 0.1 - 1 (adjustable) |
Spectral range | 8 - 14 μm |
Repeatability | ± 1°C |
Resolution | ± 1°C |
Power supply | 9V battery |
Ambient Temperature | 0°C – 40°C |
Relative Humidity | 10% - 95% RH |
Storage Temperature | -20°C to 60°C |
Dimension | 111 × 50 × 172 mm |
Net Weight | 222 g |
Employed in the food industries, for the prevention of fires of all kind, in the chemical industry, and in the storage and transportation industry.
Overall Dimension | 175 × 36 × 20 mm |
Length of probe | 106 mm |
Temperature Range | -50 °C to 300 °C (- 58 °F to 572 °F) |
Temperature Resolution | 0.1 °C |
Measurement scope | 32.00ºC to 42.99ºC (89.60ºF to 109.38ºF) Temperature <32.00ºC (89.60ºF) Display Lo ºC (Lo ºF) Temperature >42.99ºC (109.38ºF) Display Hi ºC (Hi ºF) |
Response | Approx. 10 secs |
Display | Tricolour backlight |
Backlight color interpretation | Red – Fever Orange – High Green – Normal |
Measuring range | 35°C to 42°C or 96°F to 108°F |
Accurate | 37°C+0.1°C and -0.15°C<hr> 41°C+0.1°Cand-0.15°C |
Operating temperature | 0°C-42°C |
Body | Sealed glass tube |
Temperature Range | -25℃ to 35℃ |
Dial | 150mm |
Pole Length | 100mm |
Pole Diameter | 6mm |
Measuring Temperature Range | -50 ℃ to 70 ℃<br/> -58 °F to 158 °F |
Measuring Humidity Range | 10% to 99% RH |
Temperature Resolution | 0.1 ℃ |
Temperature Accuracy | ± 1 ℃ |
Measuring temperature range | Outdoor:(-50°C~70°C) (-58°F~158°F) Indoor: (-10°C ~50°C) (32°F ~122°F) |
Humidity | 20%~99% RH |
Accuracy temperature | ±1°C (1.8°F) |
Resolution temperature | ±5%RH (40%~80%) |
Measuring temperature range | Indoor: (-10°C ~50°C) (32°F ~122°F) |
Humidity | 20%~99% RH |
Accuracy temperature | ±1°C (1.8°F) |
Resolution temperature | ±5%RH (40%~80%) |
Temperature range | - 200 °C to 500 °C |
Type | PT100 |
Resistance at 0℃ | 100±0.06 Ω<br> 100±0.12 Ω |
Insulation resistance (500VDC) | ≥100MΩ |
Type | Four-channel |
Range | K-type: -200°C to +1372°C (-328°F to + 2501°F) J type: -200°C to +1200°C (-328°F to + 2192°F) |
Accuracy | ± (0.2% + 0.7) |
Resolution | (-99.9 to + 999.9°C/°F) 0.1°C/°F (-200 to -100°C/°F, ≥ 1000°C/°F) 1°C/°F |