Vacuum Autoclave NVAC-100 is an advanced pre-vacuum steam sterilization system that removes air from the chamber before steam injection. This ensures deep, uniform sterilization of porous, wrapped, and complex instruments at 121–134°C in laboratories, hospitals, and pharmaceutical environments.
Removes air before sterilization (pre-vacuum system)
Ensures deep steam penetration
Operates at 121–134°C
Suitable for wrapped and porous loads
Includes post-vacuum drying system
NVAC-100 is used for sterilizing materials requiring complete steam penetration and validated sterilization outcomes.
Applications include:
Sterilizing surgical and wrapped instruments
Processing porous laboratory materials
Sterilizing complex medical devices
Laboratory glassware and culture media
Pharmaceutical sterile processing
Hospitals and surgical units
Pharmaceutical manufacturing plants
Biotechnology laboratories
Medical device companies
Research and diagnostic labs
PV=nRTPV = nRTPV=nRT
NVAC-100 operates through a three-stage vacuum sterilization cycle:
Pre-vacuum phase: Air is fully removed from chamber
Steam phase: Steam enters at controlled 121–134°C
Sterilization phase: Microbial inactivation occurs via heat + pressure
Post-vacuum phase: Moisture is removed for dry output
This ensures uniform sterilization even for complex internal structures and wrapped loads.
Pre-vacuum air removal system
Uniform steam penetration technology
Post-vacuum drying system
Programmable sterilization cycles
Digital monitoring of pressure & temperature
Compatibility with complex load types
Validated sterilization performance
Choose NVAC-100 if you need:
Sterilization of wrapped surgical packs
Processing of porous or complex materials
High sterility assurance level (SAL) workflows
Regulatory-compliant sterilization cycles
Avoid if:
You only need fast small instrument sterilization
You require portable/mobile sterilization
Gravity autoclaves → basic unwrapped loads
Cassette autoclaves → rapid dental/clinic cycles
Portable autoclaves → mobile field sterilization
Dry heat sterilizers → moisture-sensitive materials
Hospital surgical instrument sterilization
Pharmaceutical cleanroom sterilization
Medical device production
Laboratory media sterilization
Biotechnology research workflows
It is used for sterilizing porous, wrapped, and complex instruments requiring deep steam penetration.
Vacuum removes trapped air so steam can fully contact all surfaces for effective sterilization.
It operates between 121°C and 134°C depending on cycle type.
It is the process of removing air before steam injection to improve sterilization efficiency.
Yes, for complex and wrapped loads, vacuum autoclaves provide superior sterilization.
Yes, it is widely used for glassware and culture media sterilization.
Yes, it uses a post-vacuum drying phase.
Yes, only with dedicated liquid sterilization cycles.
Hospitals, pharma, biotech, and research laboratories.
It ensures complete and uniform sterilization of complex and wrapped loads.
Vacuum Autoclave NVAC-100 is a pre-vacuum steam sterilization system designed for deep and uniform sterilization of porous, wrapped, and complex materials. Operating at 121–134°C with programmable cycles and vacuum-assisted drying, it is widely used in hospitals, pharmaceutical industries, and laboratory environments requiring validated sterilization performance.