Tabletop Autoclave NTTA-106 is a compact laboratory steam sterilizer that uses pressurized steam at 121–134°C to sterilize instruments, glassware, culture media, and laboratory waste.
It ensures complete destruction of microorganisms and spores.
NTTA-106 is used for routine and moderate-capacity sterilization, including:
Laboratory instruments
Glassware sterilization
Culture media preparation
Small biohazard waste
It ensures contamination-free laboratory operations.
The system uses saturated pressurized steam sterilization.
Step 1: Air removal via gravity or pre-vacuum cycle
Step 2: Steam enters chamber at 121–134°C
Step 3: Heat + pressure destroy microorganisms and spores
Step 4: Controlled exhaust completes sterilization cycle
Pre-vacuum cycles improve sterilization of porous loads.
It is ideal for:
Pharmaceutical laboratories
Biotechnology labs
Hospitals and clinics
Diagnostic laboratories
Academic institutions
It ensures:
Accurate sterilization of lab materials
Prevention of contamination
Regulatory compliance
Safe handling of biohazard waste
Compact tabletop design
Gravity + pre-vacuum cycles
121–134°C sterilization range
Digital control system
Safety door lock & pressure protection
Supports solid, liquid, and porous loads
One-line takeaway: Designed for efficient sterilization in moderate laboratory environments.
Laboratory instruments
Glassware
Culture media
Liquid systems (validated cycles)
Biomedical waste
Gravity Cycle:
Used for standard non-porous loads
Pre-vacuum Cycle:
Used for porous, wrapped, or complex materials
Yes. Liquids can be sterilized using controlled steam cycles that prevent boiling, overflow, and container damage.
It operates between 121°C and 134°C, depending on cycle type and load.
Cycle duration typically ranges from 20 to 60 minutes depending on load size.
Yes. It is designed for moderate-capacity sterilization in clinical and research environments.
Automatic door locking system
Overpressure protection
Temperature monitoring
Emergency shutdown
NTTA-106 supports:
USP guidelines
ISO sterilization standards
FDA requirements
GMP laboratory practices
Choose NTTA-106 if:
Moderate sterilization capacity is needed
Space is limited
Pre-vacuum sterilization is required
You work in clinical or research labs
Not suitable if:
Large-scale industrial sterilization is required
High-capacity (>250 L+) systems are needed
Routine laboratory sterilization
Clinical instrument sterilization
Microbiology media preparation
Small waste decontamination
Tabletop Autoclave NTTA-106 is a 12 L compact steam sterilizer designed for laboratories, clinics, and research facilities. It features a microcomputer-controlled system, built-in steam generator, and operates at 134°C with a working pressure of 0.22 MPa. Equipped with multiple safety protections and automatic cycle alerts, it ensures accurate sterilization of instruments, glassware, culture media, and biohazardous waste.