Tabletop Autoclave NTTA-104 is a compact steam sterilizer that uses pressurized steam at 121–134°C to sterilize laboratory instruments, glassware, culture media, and biohazard waste.
It ensures complete elimination of microorganisms and spores in laboratory environments.
NTTA-104 is used for routine and moderate-capacity sterilization, including:
Laboratory instruments
Glassware sterilization
Culture media preparation
Small biohazard waste
It helps maintain sterile and contamination-free lab workflows.
The autoclave works using high-pressure saturated steam sterilization.
Step 1: Air removal using gravity or pre-vacuum cycle
Step 2: Steam enters chamber at 121–134°C
Step 3: Heat and pressure destroy microorganisms and spores
Step 4: Controlled exhaust completes sterilization cycle
Pre-vacuum cycles ensure deeper penetration into porous loads.
It is ideal for:
Pharmaceutical laboratories
Biotechnology research labs
Hospitals and clinics
Diagnostic laboratories
Academic institutions
It ensures:
Accurate sterilization of lab materials
Prevention of contamination
Compliance with lab safety standards
Safe handling of biohazard waste
Compact tabletop design
Gravity + pre-vacuum cycles
121–134°C sterilization range
Digital control system
Safety door lock and pressure protection
Suitable for liquid, solid, and porous loads
One-line takeaway: Designed for accurate sterilization in moderate laboratory workflows.
Laboratory instruments
Glassware
Culture media
Liquid systems (validated cycles)
Biomedical waste
Gravity Cycle:
Used for standard non-porous loads
Pre-vacuum Cycle:
Used for porous, wrapped, or complex materials
Yes. Liquids can be sterilized using controlled heating cycles that prevent boiling over and container damage.
It operates between 121°C and 134°C, depending on cycle type and load.
Typical cycle time is 20 to 60 minutes, depending on load and sterilization requirement.
Yes. It is designed for moderate-capacity sterilization in clinical, research, and diagnostic environments.
Automatic door locking system
Overpressure protection
Temperature monitoring system
Emergency shutdown system
NTTA-104 supports:
USP guidelines
ISO sterilization standards
FDA regulatory requirements
GMP laboratory practices
Choose NTTA-104 if:
Moderate sterilization capacity is needed
Space is limited
Pre-vacuum sterilization is required
You work in clinical or research labs
Not suitable if:
Large industrial sterilization is required
High chamber capacity (>200 L) is needed
Routine laboratory sterilization
Clinical instrument sterilization
Microbiology culture media preparation
Small waste decontamination
Tabletop Autoclave NTTA-104 is a compact steam sterilizer designed for laboratories, clinics, and research facilities. It ensures safe and efficient sterilization of laboratory instruments, glassware, culture media, and biohazardous waste using precisely controlled steam cycles. Equipped with advanced safety features, intuitive controls, and accurate temperature and pressure regulation, it delivers consistent sterilization performance while optimizing bench space and supporting contamination-free laboratory operations.