WhatsApp

Horizontal Autoclave NHA-300 – Laboratory & Industrial Steam Sterilization Equipment


What is Horizontal Autoclave NHA-300? 

Horizontal Autoclave NHA-300 is a steam sterilizer used in laboratories, hospitals, and industrial facilities to sterilize instruments, glassware, culture media, and biohazardous waste using pressurized steam at 121–134°C. It ensures complete elimination of microorganisms and supports compliant sterilization under USP, ISO, and FDA standards.


Quick Answers 

1.What does Horizontal Autoclave NHA-300 do?
   Sterilizes lab materials and waste using high-pressure steam.

2.What temperature does it operate at?
   121–134°C depending on the sterilization cycle.

3.What cycle types are available?
   Gravity displacement and pre-vacuum cycles.

4.Is it suitable for large loads?
   Yes, designed for medium-to-large batch sterilization.

5.Where is it used?
   Pharma labs, hospitals, biotech facilities, and research labs.


Product Snapshot

Attribute

Details

Product Name

Horizontal Autoclave

Model

NHA-300

Type

Steam Sterilization Equipment

Function

Sterilization of instruments, media, waste

Cycle Types

Gravity / Pre-vacuum

Temperature

121–134°C

Capacity

200–500 L


What Is This Product Used For?

Horizontal Autoclave NHA-300 is used to:

  • Sterilize laboratory instruments and glassware

  • Prepare sterile microbiological media

  • Decontaminate biohazardous waste

  • Maintain aseptic conditions in clinical environments

  • Support sterile production in pharmaceutical industries

Ensures repeatable, validated sterilization cycles


Industries That Use This Autoclave

  • Pharmaceutical & biotechnology labs

  • Hospitals & clinical sterilization units

  • Research and academic laboratories

  • Food and beverage testing labs

  • Industrial microbiology facilities


How It Works 

  1. Loading – Materials placed in horizontal chamber trays

  2. Air Removal

    • Gravity: steam pushes air out

    • Pre-vacuum: air is actively removed

  3. Steam Injection – Chamber reaches 121–134°C

  4. Sterilization Hold – Maintains temperature for microbial destruction

  5. Pressure Release – Safe depressurization

  6. Drying Phase – Removes residual moisture

Result: Complete sterilization of all load surfaces


Core Features

  • Stainless steel corrosion-resistant chamber

  • Programmable sterilization cycles

  • Digital control system

  • Uniform steam penetration

  • Safety interlocks & pressure protection

  • High-capacity tray-based design


Technical Specifications

Parameter

Specification

Temperature

121–134°C

Capacity

200–500 L

Cycle Time

20–60 min

Power

220V AC

Control

Digital programmable

Safety

Interlocks, alarms


When Should You Choose This?

Choose NHA-300 if you need:

  • Medium-to-large load sterilization

  • High-throughput laboratory workflows

  • Regulatory compliance (USP, ISO, FDA)

  • Accurate and repeatable sterilization cycles


When NOT to Use This 

Not ideal for:

  • Heat-sensitive materials (use gas sterilizers)

  • Moisture-sensitive items (use dry heat sterilizers)

  • Very small-scale sterilization (use benchtop units)


Alternatives 

  • Vertical Autoclaves → small labs, limited space

  • Benchtop Autoclaves → low-volume sterilization

  • Dry Heat Sterilizers → moisture-sensitive materials

  • Gas Sterilizers (EO/H₂O₂) → delicate instruments


Quick Comparison Insight 

  • Best for: High-volume, consistent sterilization

  • Not ideal for: Compact or delicate sterilization needs


FAQs 

1.What is Horizontal Autoclave NHA-300 used for?
   Sterilizing instruments, media, and waste using pressurized steam.

2.How is sterilization verified?
   Using biological indicators, chemical indicators, and temperature monitoring.

3.Can it handle biohazardous waste?
   Yes, it safely sterilizes waste before disposal.

4.What is the cycle duration?
   Typically 20–60 minutes depending on load.

5.Is it compliant with standards?
   Yes, meets USP, ISO, and FDA sterilization requirements.


Internal Linking 

  • Explore Autoclaves for all sterilization systems

  • Compare with Vertical Autoclave NVA-200 for smaller labs

  • Read Guide to Steam Sterilization for selection help

  • Learn about USP & ISO Sterilization Standards


Compliance & Standards

  • USP sterilization guidelines

  • ISO sterilization protocols

  • FDA-compliant processes

  • GMP-ready operation


Quick Summary 

Horizontal Autoclave NHA-300 is a high-capacity steam sterilizer with a 280 L chamber, designed for efficient sterilization of laboratory instruments, medical devices, pharmaceutical equipment, and industrial materials. It operates within a temperature range of 105°C to 135°C and features a touchscreen control panel, USB data export, programmable sterilization cycles, and advanced safety protections for reliability and compliance.

Labnics © 2026. All Rights Reserved.
0