WhatsApp
Product1
Product2
Product3
Product4
Glass Bead Sterilizer NGBS-101

Glass Bead Sterilizer NGBS-101

Glass Bead Sterilizer NGBS-101 offers a glass bead capacity of 600 g, providing ample space for effective decontamination. It maintains a temperature stability of ±5°C, ensuring consistent and reliable performance. This unit delivers a heating speed of ≤25 mins, minimizing downtime before sterilization. It incorporates a stainless-steel inner container, delivering durability. Our sterilizer includes a digital display that allows real-time monitoring of the internal temperature.


$1,300.00

Catalog

Specifications

Glass bead capacity 600 g
Temperature range 100°C to 300°C
Temperature stability ±5°C
Heating speed ≤25 min
Heating well volume Ф40×80 mm
Cover material Stainless steel
Insulation material Green mineral wood
Power consumption 300W
Power supply AC 220V/110V, 50/60Hz
Fuse 250V, 2A/3A Ф5×20
Dimension 130×150×240mm
Net weight 2.5 kg

Features

  • User-friendly interface
  • Low power consumption
  • Reliable heat retention
  • Portable and efficient
  • Overtemperature protection system
  • Wide temperature range

Applications

  • Glass Bead Sterilizer NGBS-101 uses heated glass beads for rapid and efficient sterilization of small lab equipment. It is commonly used in research labs, particularly for sterilizing items like forceps, scissors, scalpels, needles, and inoculation tools.

Ask Expert

FAQ for Glass Bead Sterilizer NGBS-101

1: How easy is it to monitor the sterilization process?

Our Glass Bead Sterilizer features a digital display that allows real-time monitoring of the internal temperature. This ensures you can keep track of the sterilization process without any guesswork. The clear display makes it easy to maintain the correct temperature and adjust as needed, providing a hassle-free experience for users.

2: What materials is the Glass Bead Sterilizer NGBS-101 made from?

It features a stainless-steel inner container, which provides excellent durability and resistance to corrosion, especially at high temperatures. The outer body is built to last, ensuring that the sterilizer can handle frequent use in a lab environment. It also uses green mineral wool for insulation, making it more energy-efficient and environmentally friendly.

3: Does the Glass Bead Sterilizer NGBS-101 have any safety features?

Yes, the Glass Bead Sterilizer includes overtemperature protection to prevent overheating and ensure safe operation. The precise temperature controller helps maintain a stable heat level, while the high-quality stainless-steel construction reduces the risk of burns or damage.

4: How can I clean the Glass Bead Sterilizer NGBS-101?

Cleaning the sterilizer is simple due to its stainless-steel interior, which resists stains and can be wiped down easily. You should regularly check the glass beads for cleanliness and replace them if necessary to maintain optimal performance. Always ensure that the unit is powered off and cooled down before cleaning it to avoid any risk of injury.

5: Does the Glass Bead Sterilizer make a lot of noise during operation?

No, the Glass Bead Sterilizer operates quietly, providing a peaceful work environment without unnecessary noise disruptions. The design focuses on efficient sterilization while minimizing sound, making it ideal for use in labs or clinics where a quiet environment is necessary.

6: What makes the Glass Bead Sterilizer better than other sterilizers?

Our Glass Bead Sterilizer stands out for its rapid sterilization process, heating up quickly to sterilize tools in just minutes. It uses high-quality glass beads, ensuring consistent heat distribution for effective sterilization. The built-in safety mechanisms, such as overheat protection, give you peace of mind during use.

7: How long will the glass beads last?

The glass beads in the Labnics Glass Bead Sterilizer are built to last a long time with proper care. They retain heat effectively and require minimal maintenance.

8: What happens if I leave the Glass Bead Sterilizer on for too long?

Labnics Glass Bead Sterilizer has built-in safety features to prevent overheating. It automatically shuts off if left on for too long, ensuring there’s no risk of damage or fire. This feature gives you confidence that the device will operate safely, even if you forget to turn it off right away.

9: How can I ensure the Glass Bead Sterilizer operates efficiently?

To ensure optimal performance, make sure the glass beads are kept clean and free of contaminants. Avoid overloading the sterilizer with too many instruments, as this could affect the sterilization efficiency. Regularly check the unit for any signs of wear and ensure that the temperature settings are adjusted correctly based on the instruments you're sterilizing.

Related Models Of Glass Bead Sterilizer

Labnics Glass Bead Sterilizers use heated glass beads to deliver rapid and consistent sterilization. They heat up quickly, sterilizing instruments in just minutes, enhancing workflow efficiency. These units feature a user-friendly interface with a simple control panel and easy-to-read temperature indicators. They include built-in safety mechanisms for safe operation. Our sterilizers are energy efficient, consuming minimal power while providing effective results.

Labnics © 2026. All Rights Reserved.
0