Any Query ?
Fixed Infrared Gas Analyzer NFIA-350
Fixed infrared gas analyzer NFIA-350 is a fixed model analyzer designed for monitoring, detection and analysis of combustible, toxic, poisonous gases present in severe environmental condition areas. Composed of aluminum alloy and stainless steel making it corrosion resistant. Equipped with control panel for remote controlled monitoring of large analysis area. Built-in alarm and fault relay system facilitates personnel and plant protection from flammable, toxic and oxygen hazards.
Sensor | Non-dispersive infrared sensor |
Sampling method | Diffusion |
Detection range | CO2,CH4 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Operating temperature | ( -20 °C to 55 °C ) |
Operating pressure | 86 kPa to 106 kPa |
Display panel | 4-digit LED display |
Data interface | RS485 interface |
Alarm system |
Audible ( > 90 dB ) Bright dual color LEDs |
Enclosure material | Aluminum alloy and stainless steel |
System wiring | 3-core shield cable ( 3 x 1.0 mm ) |
Protection class | IP65 |
Signal output | 4 to 20 mA |
Power supply | 24 V DC |
Weight | 1.8 kgs |
Used for the measurement and analysis of gas output or leakage in ceramic, iron-steel industry, thermal treatment, electronic, agricultural, biochemical facilities for environmental pollution regulation and energy saving.
Labnics Fixed Gas Analyzer offers continuous monitoring of combustible, toxic gases, and VOCs, ensuring real-time detection for enhanced safety. They are Control panels that enable remote monitoring of large areas for efficient gas detection. These units include an audio-visual alarm system to provide safety alerts for potential hazards. They are Constructed with corrosion-resistant aluminum alloy and stainless steel for enhanced durability.
Labnics Multi Gas Analyzer features customizable sensors for detecting various gases, offering flexibility. They provide high sensitivity and quick response times for accurate and fast gas detection. They are equipped with data storage functions and USB interfaces for convenient data management. These units are equipped with audio-visual alarm systems and vibration alerts. Our Multi-Gas Analyzers are equipped with LCDs for monitoring real-time gas concentrations.
Response time | ≤30s |
Indication error | ≤3%FS |
Gases analyzed | EX, CO, O2, H2S, NH3, Benzene gas, natural gas, CH4, fluorine, H2S, HCL, N2, H2, CL2, NOx, formaldehyde, SO2, NO, NO2, Phospine, CO2, hydrogen fluoride |
Temperature | 20-50℃ |
Sensor | Catalytic/Electrochemical/PID/Infrared |
Sampling method | Built-in pumping |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles, TVOCs |
Operating humidity | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Pump aspiration |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, PID (VOCs) and combustibles |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Sensor | Catalytic / Electrochemical / PID / Infrared sensor |
Sampling method | Pump suction type |
Detection range | H2S, CO, O2, SO2, CO2, Cl2, NH3, NO2, O3, HCN, and combustibles |
Measurement error | ≤ ± 5% FS |
Labnics Single Gas Analyzer are equipped with high-precision sensors for accurate and reliable gas detection. They are designed to be portable and compact, ensuring ease of use in diverse environments. These units feature built-in data storage for easy access and review of gas concentration data. They are built with durable, temperature- and chemical-resistant housing for reliable performance. Our units feature explosion-proof construction, ensuring safe operation in hazardous environments.
Sensor | High sensitivity sensor |
Sampling method | Diffusion |
Detection range | O2, CH4, CO, H2S, SO2, Cl2, NH3, NO2, NO, H2, HCl, HCN, CH4, PID (VOCs), CO2, C3H8 and O3 |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |
Gas detected | Acetylene C2H2 |
Sampling | With internal sampling pump, flow rate is up to 1 L/min, ten grades of pumping suction for selection |
Data logger | 100,000 data sets can be stored, with a storage space limit of 5S |
Measuring range | 0 to 50 ppm |
Labnics Wall Mounted Gas Analyzer are made from durable materials for enhanced strength and corrosion resistance. They offer LED displays for continuous and precise real-time monitoring of gas concentration levels. These units feature alarm systems for immediate notification of gas level fluctuations. They are designed with explosion-proof protection, ensuring safe operation. They offer compatibility with both Distributed Control Systems (DCS) and stand-alone operations for versatile use.
Sensor | High sensitivity sensors |
Sampling method | Diffusion |
Detection range | CO, O2, Cl2, SO2, O3, CO2, CH4, H2S, NH3, NO, NO2, H2, LEL, LPG, PID, EXP, CH4 (IR), C3H8 (IR) |
Operating humidity ( non-condensing ) | 15 % to 90 % RH |