WhatsApp
Cell Thawing System NCTS-100

Cell Thawing System NCTS-100

Cell Thawing System NCTS-100 offers 4 slots for 1.5 to 2 ml tubes to support simultaneous thawing. It completes each thawing cycle in just 2 to 3 minutes for high-speed processing. This unit operates effectively within a temperature range of 5°C to 35°C and handles room humidity levels up to 75%. It utilizes a dry heating method, eliminating water contact and reducing the risk of contamination. Our system includes a real-time touch screen for continuous slot monitoring.


$7,400.00

Catalog

Specifications

Tube capacity 1.5 to 2.0ml
Sample capacity 0.5 to 1.8ml
Thawing time 2 to 3 mins
Thawing method Dry heating method
Operating temperature 5°C to 35°C; the room humidity is 75% (max.)
Storage temperature -20℃ to 60℃
Thawing sample If the sample temperature is higher than -60°C. the device will not work, but alarm.
Thawing parameter setup Ice crystal size after thawing can be adjusted according to actual demands.
Thawing completion Notification sound, samples pop up automatically.
Sample status after thawing Ice-water mixture
Screen Touch screen real-time displays slot status
Data export Connect to the PC to export the thawing data.
Power consumption 120W
Output current 15A
Power supply AC100 to 240V/DC12V/50 to 60Hz
Product dimension 296×270×170mm
Weight 3.3 kg

Features

  • Independent channel control
  • No water contact
  • User-friendly interface
  • Expansion heating cover
  • USB data connectivity
  • Safe sample handling

Applications

  • Cell Thawing System NCTS-100 is used to rapidly and safely thaw cryopreserved cells or biological samples while preserving their viability and integrity. It is commonly applied in cell therapy labs, biopharmaceutical manufacturing, clinical research facilities, and biobanks.

Ask Expert

FAQ for Cell Thawing System NCTS-100

1: Is the thawing process fully automatic?

Yes, the entire thawing process is automatic, including a pop-up mechanism and audible alert once thawing is complete. This reduces manual handling and enhances consistency across samples.

2: Does the Cell Thawing System NCTS-100 use water for heating?

No, our Cell Thawing System uses a dry heating method, eliminating any contact with water. This greatly reduces the risk of contamination and makes the system more hygienic and easier to maintain.

3: How does the Cell Thawing System NCTS-100 ensure temperature uniformity?

The Cell Thawing System uses four-way air convection technology to distribute heat evenly across all sample slots. This ensures consistent and reliable thawing conditions for every sample.

4: Can each thawing slot be used independently?

Yes, all four slots operate independently, allowing different samples to be thawed under separate conditions at the same time. This offers flexibility for varied sample types and workflows.

5: How does the Cell Thawing System NCTS-100 prevent cross-contamination?

The Cell Thawing System eliminates water use by relying on dry heat, which reduces microbial growth and cross-contamination risk. This makes it safer and cleaner than traditional water-based thawing methods.

6: Does the Cell Thawing System require regular maintenance?

Yes, regular maintenance ensures optimal performance and longevity. However, the dry heating design reduces the need for intensive cleaning compared to water-based systems.

7: How does the Cell Thawing System improve lab efficiency?

The Cell Thawing System speeds up the thawing process while handling multiple samples at once. This not only saves time but also ensures consistent sample quality, improving overall lab productivity.

8: Is the Cell Thawing System safe to use with sensitive samples?

Yes, our Cell Thawing System is specifically engineered to protect cell viability during thawing. The uniform heat transfer and controlled settings reduce the risk of damaging delicate samples.

9: How often does the Cell Thawing System require maintenance?

The Cell Thawing System requires minimal maintenance due to its robust design. Routine cleaning and periodic performance checks are usually sufficient to keep it in optimal working condition.

10: What parts of the Cell Thawing System need regular cleaning?

The tube slots and exterior surfaces should be cleaned regularly to prevent contamination. A soft cloth and non-corrosive disinfectant are recommended for cleaning.


Cell Thawing System NCTS-100

Cell Thawing System NCTS-100

Related Models Of Cell Thawing System

Labnics Cell Thawing Systems are designed to rapidly and uniformly thaw cryopreserved biological samples. They feature multiple tube slots that accommodate several cryovials simultaneously, enabling higher throughput. These units complete the thawing process within minutes to maintain cell integrity. They provide uniform temperature distribution to prevent thermal shock. Our systems include a user-friendly interface with simple controls and clear indicators.