Multi-Parameter Water Quality Analyzer NMWA-100 offers a comprehensive solution for assessing water quality by measuring multiple parameters simultaneously, providing accurate, real-time data for various applications. Incorporates a dual temperature zone design with 6+6 zones operating at 165°C and 60°C allowing simultaneous operation without interference. User-friendly interfaces, with intuitive controls and displays to facilitate easy operation and data interpretation.
COD Measurement Range | 0-15000mg/L |
Ammonia Nitrogen Measurement Range | 0-160mg/L |
Phosphorus Measurement Range | 0-100mg/L |
Nitrogen Measurement Range | 0-150mg/L |
SS Measurement Range | 0.5-1000 mg/L |
Turbidity Measurement Range | 0.5-400 NTU |
COD Measurement Accuracy | COD<50mg/L,≤±10% COD>50mg/L,≤± 5% COD>50mg/L,≤± 5% |
Ammonia Nitrogen Accuracy | ≤±5% |
Phosphorus Accuracy | ≤±5% |
Nitrogen Accuracy | ≤±5% |
SS Accuracy | ≤±5% |
Turbidity Accuracy | ≤±5% |
COD Detection Limit | 0.1mg/L |
Ammonia Nitrogen Detection Limit | 0.01mg/L |
Phosphorus Detection Limit | 0.002mg/L |
Nitrogen Detection Limit | 0.1mg/L |
SS Detection Limit | 1mg/L |
Turbidity Detection Limit | 0.5NTU |
COD Time Range | 20min |
Ammonia Nitrogen Time Range | 10~15min |
Phosphorus Time Range | 35~50min |
Nitrogen Time Range | 45 to 50min |
SS Time Range | 1min |
Turbidity Time Range | 1 min |
COD Batch Processing | 12 |
Ammonia Nitrogen Batch Processing | No limit |
Phosphorus Batch Processing | 12 |
Nitrogen Batch Processing | 12 |
SS Batch Processing | No limit |
Turbidity Batch Processing | No limit |
COD Repeatability | ≤±5% |
Ammonia Nitrogen Repeatability | ≤±5% |
Phosphorus Repeatability | ≤±5% |
Nitrogen Repeatability | ≤±5% |
SS Repeatability | ≤±5% |
Turbidity Repeatability | ≤±5% |
Lamp Life | 100000 hours |
Optical Stability | ≤±0.001A/10min |
COD Anti chlorine Interference | [Cl-]<1000mg/L has no effect [Cl-]<4000mg/L(optional) |
Colorimetric Method | 16mm/25mm Tube,10mm/30mm Cuvette |
Data Storage | 50 million |
COD Digestion Temperature | 165℃±0.5℃ |
Phosphorus Digestion Temperature | 120℃±0.5℃ |
Nitrogen Digestion Temperature | 122℃±0.5℃ |
COD Digestion Time | 10 min |
Phosphorus Digestion Time | 30 min |
Nitrogen Digestion Time | 40 min |
Time switch | Automatic |
Temperature Range | RT ±5-190℃ |
Temperature Indication Error | <±2℃ |
Uniformity | ≤2℃ |
Time Range | 1-600 min |
Power Consumption | 180W |
Rated Voltage | 24 V |
Ambient Temperature | 5 to 40 ℃, |
Relative Humidity | ≤85% |
Host Dimemsion | 430 × 345 × 188 mm |
Experiment Box Dimension | 479 × 387 × 155 mm |
Host Weight | 11.9 Kg |
Test Box Weight | 7 Kg |