Flow Cytometer NFC-101 Catalog

Flow Cytometer NFC-101 features a fully automatic detection process that handles up to 50,000 events per second. It supports 40-tube rotary samplers and 96-well microplates, providing versatility and efficiency in sample processing. Our cytometer is equipped with up to three powerful lasers for excitation at 405nm (100mW), 488nm (60mW), and 638nm (80mW). It utilizes a plunger pump and a volume-based method for precise cell counting.

FEATURES

  • Automatic fluorescence compensation
  • Flexible injection options
  • Quick loading efficiency
  • Simple and efficient operation
  • Avalanche photodiode detector
SPECIFICATIONS
Laser Configuration Up to 3 lasers 405nm (100mW ) , 488nm (60mW ) , 638nm (80mW )
Detection Speed >50000 events/s
Resolution <2%
Fluorescence Detection Limit FITC<50MESF; PE<30MESF; APC<30MESF
Fluorescence Linearity ≥0.99
Detector APD Detector
Forward Scattered Light Resolution <0.45um
Detection Particle Range 0.2-50um
Carryover Rate <0.1%
Absolute Count Compatible with volumetric and microsphere absolute counting
Signal Range Maximum10⁷
Injection Speed Low: 15uL/min; Medium: 30 uL/min; High 1: 60 uL/min; High2: 90uL/min; High 3: 120 uL/min Adjustable speed range: 15-120 u L/min
Threshold Setting Supports dual thresholds to minimize cell debris
Fluorescence Compensation Support automatic online compensation, offline compensation and visual compensation tools
Project Template Support project template function, one-click calling of acquisition conditions/fluorescence compensation information
Instrument Quality Control Automatic daily QC inspection, tracking and recording through Levery-Jennings
Injection Mode Single tube manual sampling 40 tubes auto sampler with single sample mixing function 96-hole plates
Software support acquisition and analysis at the same time
File Format Support FCS3.1/FCS3.0 and FCS2.0 format files
Maintenance Method Startup initialization, startup cleaning, cleaning between experiments, shutdown cleaning, exhaust bubble, etc Automatic maintenance procedure for monthly cleaning (deep cleaning)
Computer Configuration DELL/CPU I5/Memory 8G/HDD 1T/27 inch monitor
Dimensions(L× W × H) 760 × 450 × 470 mm
Weight 40 Kg
APPLICATIONS
Flow cytometer is widely used in various fields such as oncology, immunology, stem cell research, hematology, cell biology, oceanography, environmental monitoring, and clinical diagnostics.
STANDARD ACCESSORIES
Fuse × 2pcs
Liquid Sensor × 4pcs
Bucket Rack × 1 pcs
Waste Liquid Bucket × 1pcs
Sheath Liquid Bucket × 1pcs
Cleaning Liquid Bucket × 1pcs
Shutdown Liquid Bucket × 1pcs
Single Tube Subassembly
Sensor cable Holder
Cable
Computer
USB 3.0
OPTIONAL ACCESSORIES
40 Rotary
96-Well microplate-shallow
96-Well microplate-deep
40 Rotary+96 well microplate (Shallow)