BOD Meter NBOD-100 it fully stimulates the natural biodegradation of organics. It automatically prints the daily data. It has maximum measuring range of 0 to 4000 mg/L. Equipped with color liquid crystal display screen to view the sample values with different colors. Culture period can be adjusted according to the demand which can choose 1 to 7 days.
Specifications
Measurement range | 0 to 4000mg/L |
Measuring error | ±10% |
Cycle length | 5days |
Measure amount | 6 |
Culture bottle volume | 580ml |
Data storage | 5 years |
Communication | USB transmission, infrared transmission (optional) |
Culture temperature | 20±1 |
Working power | 110 to 230V 50 to 60HZ |
Rated power | 24W |
Features
Applications
Ask Expert
Measurement range | 0-4000mg/L |
Measuring error | ±10% |
Cycle length | 5 days |
Measuring range | 0 to 4000 mg/L |
Measuring error | ±10% |
Resolution | 2 mg/L |
Measuring Principle | Manometric; mercury-free; electronic pressure sensor |
Measuring Range | 0 to 40, 0 to 80, 0 to 200, 0 to 400, 0 to 800, 0 to 2000, 0 to 4000 mg/l |
Measurement Time | User-selectable, between 1 and 28 days |
Measurement range | 0-4000 mg/L |
Measurement accuracy | ±8% |
Resolution | 0.01 mg/L |
High COD Range | 20 to 10000mg/L |
Low COD Range | 2 to 150mg/L |
Accuracy for COD < 50mg/L | ≤ ±5% |
Digestion capacity | 9 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 100 mm |
Digestion capacity | 16 samples per run |
Vial capacity | 19 ml |
Vial dimension | Ф16×145 mm |
Model no | NCCA-100 |
Measuring range | k= 1 0~2000μS/cm |
Resolution | 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm |
Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.
Conductivity specifications:- Conductivity range | 0.000µS/cm ~ 1000mS/cm |
Conductivity resolution | 0.001µS/cm |
Conductivity accuracy | ± 1.0% (FS) |
Measurement Range | 0 to 400 mS/cm |
Resolution | 0.001 μS/cm to 0.1 mS/cm |
Indication Error | ±0.5% F.S |
Conductivity range | 0.000 μS/cm to 500 mS/cm |
Conductivity resolution | 0.001 μS/cm minimum, various range selection |
Conductivity accuracy | ±1.0% FS |
Dissolved Oxygen Range | 0.00-20.00mg/L |
Dissolved Accuracy | ±0.2mg/L |
Dissolved Resolution | 0.01 mg/L |