Any Query ?
Automatic Kinematic Viscometer NAKV-101
Automatic Kinematic Viscometer NAKV-101 offers an adjustable temperature control range from room temperature to 120 °C. It features an imported PT100 temperature sensor, providing high-temperature accuracy. This Viscometer allows simultaneous measurement of 4 samples, enabling independent testing. It includes a 5.6-inch high-definition color touchscreen for a user-friendly interface. Our unit allows users to set and save various parameters for enhanced operational efficiency.
Temperature control range | Room temperature to 120 °C can be adjusted |
Temperature control accuracy | ± 0.05 ° C |
Ambient temperature | 5 to 40 ° C |
Ambient Humidity | < 85%RH |
Number of bath holes | 4 |
Number of experiments | 1-9 times (adjustable) |
Power Supply | AC220 ± 10% 50HZ |
Power Consumption | 1200W |
Dimensions | 550 × 410 × 570 mm |
Weight | 21 Kgs |
Automatic Kinematic Viscometer NAKV-101 is used for precisely measuring the viscosity of liquids in various industries, ensuring consistent quality control. It is commonly applied in petroleum, food, and chemical sectors for product formulation and testing.
Fuse (10A) × 1
Measurement range | 25 mPa.s to 1×10000000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min |
Temperature control range | 45 to 200°C |
Measurement range | 100 mPa.s to 200000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | 5, 10, 20, 50 r/min |
Temperature control range | Room temperature to 200°C |
Speed | 0.1 to 200 infinitely variable speed, a total of 2000 speed options |
Measuring Range | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Rotor 1 – 4</td> <td style=min-width:50px>10 to 6 M mPa. s</td> </tr> <tr> <td style=min-width:50px>ULR</td> <td style=min-width:50px>1 to 6 K</td> </tr> <tr> <td style=min-width:50px>Rotor 18</td> <td style=min-width:50px>1.5 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 25</td> <td style=min-width:50px>240 to 4.8 M</td> </tr> <tr> <td style=min-width:50px>Rotor 31</td> <td style=min-width:50px>15 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 34</td> <td style=min-width:50px>30 to 600 K</td> </tr> </table> |
Display Mode | 5-inch color touchscreen |
Rotor | L1 – L4 (Standard); Enhanced Ultra – low Viscosity adapter ULR (optional); Small sample adapters (rotors 18, 25, 31, 34) (optional) |
Temperature control range | Room temperature - 120°C |
Temperature control precision | ≤ ± 0.01°C |
No. of liquid bath hole | 4 |
Test times | 1 to 6 time/times, adjustable |
Temperature control range | -40°C - 60°C |
Temperature control precision | ≤ ± 0.03°C |
No. of liquid bath hole | 2 |
Test times | 2 to 6 time/times, adjustable |
Temperature control range | RT to 150℃ |
Temperature setting | 20℃, 40℃, 50℃, 80℃, 100℃, any value (higher than room temperature to 150℃) |
Temperature control accuracy | ± 0.1℃ |
Timing range | 0 to 999s |
Temperature range | Ambient to 100.0℃ |
Temperature control accuracy | ±0.01℃ |
Bath capacity | 20L |
Timing range | 0.0s to 9999.9s |
Temperature control range | Room temperature to 100°C |
Measuring range | Kinematic viscosity: 0.5 to 20000mm²/s<br/> Dynamic viscosity: 0. 3 to 40000mPa.s |
Temperature control accuracy | 0.01℃ |
Ambient temperature | 15 to 35°C |
Measuring parameters | Kinematic Viscosity, Dynamic Viscosity, Density, Viscosity Index |
Measuring Viscosity Range | 0.2 to 30,000 mm²/s |
Measuring Density Range | 0 to 3 g/cm³ |
Temperature Range | -60℃ to 140℃ |
Measuring range | 0.1 to 2,000,000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±0.5% |
Measuring range | 1 to 200000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 600000 mPa.s |
Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |