Platinum Resistance Thermometer NPRT-100 is designed for accurate and stable temperature measurements within a temperature range of -200°C to 500°C. It utilizes platinum element with a glass wire-wound construction for precise temperature measurement and minimal resistance drift. It delivers quick responses in less than 5 seconds, providing rapid and accurate readings.
Temperature range | - 200 °C to 500 °C |
Type | PT100 |
Resistance at 0℃ |
100±0.06 Ω 100±0.12 Ω |
Insulation resistance (500VDC) | ≥100MΩ |
Dielectric strength | 2KV/AC 50Hz/1min |
Time constant (t0.5) | ≤1 seconds |
D1 | ≥ 3±0.1 (mm) |
D2 | ≥ 5±0.1 (mm) |
L1 | ≥ 20±1 (mm) |
L2 | ≥ 50±1 (mm) |
L3 | any length |
Number of Wires | 2, 3 and 4 |
Cable | Range: AWG 26 to AWG 22 Standard Size: AWG 24 |
Platinum Resistance Thermometer NPRT-100 is widely utilized in Industrial Processes, Scientific Research, Calibration, HVAC systems and Cryogenic applications.
Overall Dimension | 175 × 36 × 20 mm |
Length of probe | 106 mm |
Temperature Range | -50 °C to 300 °C (- 58 °F to 572 °F) |
Temperature Resolution | 0.1 °C |
Measurement scope | 32.00ºC to 42.99ºC (89.60ºF to 109.38ºF) Temperature <32.00ºC (89.60ºF) Display Lo ºC (Lo ºF) Temperature >42.99ºC (109.38ºF) Display Hi ºC (Hi ºF) |
Response | Approx. 10 secs |
Display | Tricolour backlight |
Backlight color interpretation | Red – Fever Orange – High Green – Normal |
Measuring range | 35°C to 42°C or 96°F to 108°F |
Accurate | 37°C+0.1°C and -0.15°C<hr> 41°C+0.1°Cand-0.15°C |
Operating temperature | 0°C-42°C |
Body | Sealed glass tube |
Optical resolution | 30:01 |
Measuring range | -50 °C to 750 °C |
Measuring accuracy | ± 2°C |
Response time | 500 ms |
Temperature Range | -25℃ to 35℃ |
Dial | 150mm |
Pole Length | 100mm |
Pole Diameter | 6mm |
Measuring Temperature Range | -50 ℃ to 70 ℃<br/> -58 °F to 158 °F |
Measuring Humidity Range | 10% to 99% RH |
Temperature Resolution | 0.1 ℃ |
Temperature Accuracy | ± 1 ℃ |
Measuring temperature range | Outdoor:(-50°C~70°C) (-58°F~158°F) Indoor: (-10°C ~50°C) (32°F ~122°F) |
Humidity | 20%~99% RH |
Accuracy temperature | ±1°C (1.8°F) |
Resolution temperature | ±5%RH (40%~80%) |
Measuring temperature range | Indoor: (-10°C ~50°C) (32°F ~122°F) |
Humidity | 20%~99% RH |
Accuracy temperature | ±1°C (1.8°F) |
Resolution temperature | ±5%RH (40%~80%) |
Type | Four-channel |
Range | K-type: -200°C to +1372°C (-328°F to + 2501°F) J type: -200°C to +1200°C (-328°F to + 2192°F) |
Accuracy | ± (0.2% + 0.7) |