WhatsApp
Organic Element Analyzer NOEA-100

Organic Element Analyzer NOEA-100

Organic Element Analyzer NOEA-100 measures carbon and nitrogen from 0.002 to 20 mg using dual furnaces for rapid elemental analysis. This unit features a stable frame and touchscreen interface for seamless operation. It ensures accurate readings through automatic leak detection and controlled oxygen flow. This analyzer supports pneumatic, electric, and manual sample loading to accommodate varied formats. Our system handles both solids and liquids with high-sensitivity gas chromatography.


$115,875.00

Catalog

Specifications

Measuring Range Carbon: 0.002 to 20 mg
Nitrogen: 0.002 to 20 mg
Sample Type Solid, liquid
Sample Size 0 to 500 mg (depending on nature)
Accuracy <0.2% (standard, purity >99.9%)
Precision <0.1% (standard, purity >99.9%)
Standby Mode Yes
Sampler Pneumatic: 147-bit
Electric: 32, 50, 100-bit
Manual sampler
Gas Requirements He (99.999%), O₂ (99.999%), 3 to 5 bar; air (oil-free compressed)
Carrier Gas Helium
Reactor Temperature Left: max 1100 °C; Right: max 1100 °C
Separator Furnace Temp Max. 110 °C
Oxygen Requirement Automatically calculated from oxygen gauge
Gas Separation 3 m GC column
Detector High-sensitivity TCD
Software EAS Clarity
Calibration Method Linear, conic, cubic
Bag Sample High purity tin/silver cup
Power Consumption 5A, 1100 Wh
Power Supply 230V, 50/60 Hz
Dimensions (L×W×H) 810 × 500 × 370 mm
Weight 68 kg

Features

  • REDOX tube options
  • Temperature regulation unit
  • Integrated drying system
  • Oxygen supply monitor
  • Chromatography output port

Applications

  • Organic Element Analyzer NOEA-100 ensures fast CN quantification using sealed combustion and GC-based analysis. It is used in petrochemical testing, food inspection, and pharmaceutical QA workflows.

Optional Accessories

Automatic sampler 98 holes × 1 

Automatic sampler 147 holes × 1

Optional Consumables

1000 CHNS Analysis Consumables Kit × 1

Ask Expert

FAQ for Organic Element Analyzer NOEA-100

1: How does Organic Element Analyzer NOEA-100 manage high-temperature operation during CN detection?

Labnics Organic Element Analyzer uses a dual-furnace configuration with built-in thermal controls to maintain combustion conditions. This setup helps ensure full reaction and consistency across different material types.

2: Can Organic Element Analyzer NOEA-100 support multiple types of sample delivery?

Yes, Organic Element Analyzer supports pneumatic, electric, and manual sampling modes. This flexibility helps match different lab workflows and simplifies switching between low and high-throughput tasks.

3: What separation method does Organic Element Analyzer NOEA-100 use for analysis?

Our Organic Element Analyzer uses a gas chromatography column to separate combustion gases before detection. This system helps isolate carbon and nitrogen signals clearly without overlapping peaks.

4: What kind of detector is integrated in Organic Element Analyzer NOEA-100?

Organic Element Analyzer includes a thermal conductivity detector that captures signal variations with high sensitivity. Labnics supports accurate analysis across both trace and bulk CN sample ranges.

5: How is oxygen regulation maintained in Organic Element Analyzer NOEA-100?

Labnics Organic Element Analyzer features automated oxygen flow monitoring and system alerts for pressure inconsistencies. This ensures combustion is carried out under stable and controlled conditions throughout testing.

6: How do Organic Element Analyzers maintain long-term detection accuracy?

Labnics Organic Element Analyzers use drift-free thermal sensors with regulated combustion chambers to minimize variation. These components deliver stable readings across multiple runs and reduce recalibration needs during long-term use.

7: What detection methods are used in Organic Element Analyzers?

Yes, Organic Element Analyzers operate on thermal conductivity or gas chromatography principles to evaluate CHNS content. These detection methods provide clear resolution across various sample types and maintain high analytical precision.

8: How do Organic Element Analyzers manage different sample types?

Our Organic Element Analyzers process solids, powders, and semi-solids without extensive preparation. Integrated loading units and heat-stable containers allow uniform sample handling throughout analysis cycles.

9: How is operational data captured and exported in Organic Element Analyzers?

Organic Element Analyzers store results internally and support direct data transfer through USB or external output. This ensures reliable documentation, quick access to past records, and smooth integration with lab data systems.

Related Models Of Organic Element Analyzer

Organic Element Analyzers measure carbon, hydrogen, nitrogen, and sulfur in various materials. These systems use thermal conductivity or gas chromatography with high-temperature combustion. They support powders, solids, and particulates while maintaining repeatable detection across all formats. These analyzers perform CHNS evaluation through user-defined programmable cycles. Our analyzers feature built-in filtration units and automated samplers for smooth operation.

Labnics © 2025. All Rights Reserved.