Organic Element Analyzer NOEA-101 offers a measuring range of 0.002 to 20 mg for C, H, N, S, and O analysis. This system operates with a single furnace and handles up to 1000 mg of solid or liquid samples. It ensures accuracy with automatic oxygen regulation and gas flow control. This unit integrates temperature control, sample processing, and real-time data output. Our analyzer includes a leak-tight design and internal diagnostics for reliable, repeatable testing cycles.


$116,175.00

Catalog

Specifications

Measuring Range Carbon: 0.002 to 20 mg
Hydrogen: 0.002 to 5 mg
Nitrogen: 0.002 to 20 mg
Sulfur: 0.002 to 6 mg
Oxygen: 0.002–2 mg
Sample Type Solid, liquid
Sample Size 0.1 to 500 mg; up to 1000 mg for soil
Accuracy < 0.2% (standard, purity >99.9%)
Precision < 0.1% (standard, purity >99.9%)
Standby Mode Yes
Sampler Pneumatic, electric (32, 50, 100 bit), and manual
Gas Requirements Helium, Oxygen (99.999%, 3 to 5 bar), oil-free compressed air
Carrier Gas Helium
Reactor Temperature Max 1100 °C
Separator Furnace Temp Max. 110 °C
Oxygen Requirement Automatically calculated from oxygen gauge
Gas Separation 0.8 to 4 m GC column
Detector High sensitivity TCD
Software EAS Clarity
Calibration Method Linear, conic, cubic
Bag Sample High purity tin/silver cup
Power Consumption 900 W (4 A)
Power Supply 230 V, 50/60 Hz
Dimensions (L×W×H) 510 × 500 × 370 mm
Weight 53 kg

Features

  • GC column separation
  • Multi-sampler support
  • Clarity software link
  • Reagent inlet system
  • Elemental calibration modes

Applications

  • Organic Element Analyzer NOEA-101 measures CHNSO content in solid and liquid samples using gas chromatography and thermal conductivity detection. It is used in laboratories handling environmental analysis, soil science, and chemical testing workflows.

Optional Accessories

Automatic sampler 98 holes × 1 

Automatic sampler 147 holes × 1

Optional Consumables

500 O Analysis Consumables Kit × 1

1000 CHNS Analysis Consumables Kit × 1

Ask Expert

FAQ for Organic Element Analyzer NOEA-101

1: How does Organic Element Analyzer NOEA-101 control gas flow accuracy during testing?

Labnics Organic Element Analyzer uses real-time monitoring to maintain gas stability throughout the cycle. Its software adapts flow rates based on sample behavior. This prevents oversaturation or incomplete combustion. Consistent regulation ensures precise measurements.

2: Can Organic Element Analyzer NOEA-101 support solid and liquid testing without format change?

Yes, Organic Element Analyzer accepts diverse sample states with no major hardware adjustment. Its chamber design supports uniform combustion. Gas pathways are calibrated for multiphase materials. This allows seamless switching between formats.

3: How does Organic Element Analyzer NOEA-101 minimize downtime during multi-sample processing?

Our system features a secure mounting interface and user-guided operation. It supports fast sample replacement with minimal calibration shifts. The touchscreen provides access to diagnostics and logging. This ensures workflow continuity without delay.

4: What safety checks are built into Labnics Organic Element Analyzer NOEA-101?

Labnics Organic Element Analyzer offers internal leak detection, flow error alerts, and self-check diagnostics. These systems reduce operational hazards and ensure stable output. Users receive instant visual prompts. Routine functions are auto-verified before every run.

5: Does Organic Element Analyzer NOEA-101 allow calibration without interrupting the current setup?

Yes, Organic Element Analyzer supports background calibration scheduling. It permits system alignment between test cycles. Users can adjust parameters without halting analysis. This maximizes accuracy without interrupting workflows.

6: How do Organic Element Analyzers maintain long-term detection accuracy?

Labnics Organic Element Analyzers use drift-free thermal sensors with regulated combustion chambers to minimize variation. These components deliver stable readings across multiple runs and reduce recalibration needs during long-term use.

7: What detection methods are used in Organic Element Analyzers?

Yes, Organic Element Analyzers operate on thermal conductivity or gas chromatography principles to evaluate CHNS content. These detection methods provide clear resolution across various sample types and maintain high analytical precision.

8: How do Organic Element Analyzers manage different sample types?

Our Organic Element Analyzers process solids, powders, and semi-solids without extensive preparation. Integrated loading units and heat-stable containers allow uniform sample handling throughout analysis cycles.

9: How is operational data captured and exported in Organic Element Analyzers?

Organic Element Analyzers store results internally and support direct data transfer through USB or external output. This ensures reliable documentation, quick access to past records, and smooth integration with lab data systems.

Related Models Of Organic Element Analyzer

Organic Element Analyzers measure carbon, hydrogen, nitrogen, and sulfur in various materials. These systems use thermal conductivity or gas chromatography with high-temperature combustion. They support powders, solids, and particulates while maintaining repeatable detection across all formats. These analyzers perform CHNS evaluation through user-defined programmable cycles. Our analyzers feature built-in filtration units and automated samplers for smooth operation.

Labnics © 2025. All Rights Reserved.