Benchtop Multi-Parameter Meter NBMM-101 offers a wide pH measurement range from -2.000 to 20.000 for diverse testing needs. It features a real-time clock that complies with GLP standards for reliable time tracking. This meter provides self-calibration along with built-in reminders for timely adjustments. It provides automatic temperature compensation, ensuring accurate readings. Our unit includes a large backlit LCD for clear and easy viewing of data.


Catalog

Specifications

Test parameters pH, conductivity, temperature, salinity, TDS, and dissolved oxygen
pH Range -2.000 to 20.000 pH
pH Accuracy ±0.002pH
pH Resolution 0.1, 0.01, 0.001pH, Selectable
pH Calibration Points 1 to 5 points
pH Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0 to 100°C, 32 to 212°F
mV Range (-1999.9 to 1999.9) mV
mV Accuracy ±0.2mV
mV Resolution 0.1, 1mV, Selectable
mV Calibration Points 1 point (Only for Relative mV mode)
mV Measurement Modes Relative or absolute mV
Conductivity Range 0.01 to 20.00mS/cm
Conductivity Accuracy ±0.5% F. S
Conductivity Resolution 0.001,0.01,1, Automatic
Conductivity Calibration Points 1 to 5 points
Temperature Coefficient Linear(0.0to10.0%/°C) or pure water compensation
Cell Constant K=0.1,1,10 or custom
Reference Temperature 20°C or 25°C
DO Range 0.00to20.00mg/L
DO Accuracy ±0.2mg/L
DO Resolution 0.01, 0.1mg/L, selectable
% Saturation of Oxygen 0.0 to 200.0%
% Saturation Accuracy ±2.0%
% Saturation Resolution 0.1, 1%, selectable
Calibration Points 1 or 2 points
Pressure Correction 60.0 to 112.5kPa, 450 to 850mmHg, manual
Salinity Correction 0to50g/L, manual
Temperature Range 0 to105°C, 32to221°F
Temperature Accuracy ±0.5°C, ±0.9°F
Temperature Resolution 0.1°C, 0.1°F
Offset Calibration 1 point
Calibration Range Measured value ±10°C
Power Supply DC5V, using AC adapter, 220V/50Hz
Dimensions 430 × 310 × 100 mm
Weight 5 kg

Features

  • Automatic electrode diagnosis
  • Supports storage of 500 readings
  • Auto Reset and hold function
  • Selectable pH buffer standard
  • USB interface for data transfer
  • Electrode slope auto display

Applications

  • Benchtop Multi-Parameter Meter is used for the measurement of various parameters such as pH, conductivity, and temperature. It is commonly used in laboratories for research, quality control, and environmental analysis.

Standard Accessories

pH electrode
Temperature probe
pH buffer solutions (pH 4.0/7.00/10.01)
DC9V power adapter

Ask Expert

Related Models Of Multi-Parameter Meter (Benchtop)

Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.

Benchtop Multi-Parameter Meter NBMM-100

pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Catalog

Benchtop Multi-Parameter Meter NBMM-102

pH Range -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy ±0.002 pH
Catalog

BOD Meter

BOD Meter NBOD-100

Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Catalog

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Catalog
BOD Meter NBOD-102
Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Catalog

COD Analyzer

COD analyzer NCA-100
High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Catalog

COD Digester

Benchtop COD Digester NBCD-100

Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Catalog

Benchtop COD Digester NBCD-101

Digestion capacity 16 samples per run
Vial capacity 19 ml
Vial dimension Ф16×145 mm
Catalog

Conductivity Controller Analyzer

Conductivity Controller Analyzer NCCA-100
Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Catalog

Conductivity Meter (Portable)

Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.

Portable Conductivity Meter NCM-100
Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Catalog

Portable Conductivity Meter NCM-200

Measurement Range 0 to 400 mS/cm
Resolution 0.001 μS/cm to 0.1 mS/cm
Indication Error ±0.5% F.S
Catalog

Portable Conductivity Meter NCM-201

Conductivity range 0.000 μS/cm to 500 mS/cm
Conductivity resolution 0.001 μS/cm minimum, various range selection
Conductivity accuracy ±1.0% FS
Catalog