WhatsApp
Benchtop Multi-Parameter Meter NBMM-100

Benchtop Multi-Parameter Meter NBMM-100

Benchtop Multi-Parameter Meter NBMM-100 is a laboratory apparatus designed for measurement of pH, conductivity, temperature, salinity, TDS etc of water and various industrial samples. It is equipped with built-in real-time clock that meets the GLP regulatory standards of any laboratory setting. It enables automatic temperature compensation for accurate display of reading value over the entire pH range and other parameters. The subsequent reminder alerts for calibration aids in maintaining the smooth functionality of a meter.


Catalog

Specifications

pH Specifications:- Range (-2.000~20.000) pH
Accuracy ±0.002pH
Resolution 0.1, 0.01, 0.001pH, Selectable
Calibration Points 1 to 5 points
Calibration Solutions USA, NIST, DIN or User-defined
Temperature Compensation 0~100°C, 32~212°F
mV Range (-1999.9~1999.9) mV
mV Accuracy ±0.2mV
mV Resolution 0.1, 1mV, Selectable
mV Calibration Points 1 point (Only for Relative mV mode)
mV Measurement Modes Relative or absolute mV
Conductivity Range 0.01~20.00,200.0,2000µS/cm,20.00,200.0mS/cm
Conductivity Accuracy ±0.5% F.S
Conductivity Resolution 0.001,0.01,1, automatic
Conductivity Calibration Points 1 to 5 points
Conductivity Calibration Solutions 10µS/cm,84µS/cm,1413µS/cm,12.88mS/cm,111.8 mS/cm
Temperature Coefficient Linear(0.0~10.0%/°C) or pure water compensation
Cell Constant K=0.1,1,10 or custom
Reference Temperature 20°C or 25°C
TDS Range 0~10.00,100.0,1000ppm,10.00,100.0ppt(max 200ppt)
TDS Accuracy ±1%F.S
TDS Resolution 0.01,0.1,1, automatic
TDS factor 0.1~1.0(Default 0.5)
Salinity Range 0.00~80.00ppt,0.00~42.00psu
Salinity Accuracy ±1%F.S
Salinity Resolution 0.01
Measurement Modes Practical salinity(psu) or natural seawater(ppt)
Resistivity Range 0.00-20.00MΩ
Resistivity Accuracy ±1%F.S
Resistivity Resolution 0.01
General Temperature Compensation 0~100°C,32~212°F, manual or automatic
Stability Criteria Low or high
Calibration Due Alarm 1 to 31 days or off
Power Supply DC5V,AC 220V/50Hz
Overall Dimensions(L×W×H) 210×188×60 mm
Weight 1.5kg

Features

  • Large backlit LCD display
  • Selectable pH buffer standard (USA/NIST/DIN) for automatic calibration
  • Automatic electrode slope display to guide the user whether to replace sensor
  • Easy reading and recording of measured data with Auto-Hold function
  • Selectable temperature unit (°C or °F) meets different application requirements
  • Automatic electrode diagnosis shows zero point offset and slopes of the pH electrode
  • Automatic Reset function resumes all parameters back to factory default settings
  • Expandable memory stores and recalls up to 500 readings
  • Easy transfer of data via USB communication interface

Applications

  • It has multidisciplinary applications in areas like research and development, water testing laboratories, sewage water treatment plant, brewing and wine industries, healthcare and clinical applications etc.

Standard Accessories

Accessories No Name
1 pH electrode
2 Temperature probe
3 pH buffer solutions (pH 4.0/7.00/10.01)
4 DC9V power adapter

Ask Expert

Related Models Of Multi-Parameter Meter (Benchtop)

Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.

Benchtop Multi-Parameter Meter NBMM-101

Test parameters pH, conductivity, temperature, salinity, TDS, and dissolved oxygen
pH Range -2.000 to 20.000 pH
pH Accuracy ±0.002pH
Catalog

Benchtop Multi-Parameter Meter NBMM-102

pH Range -2.000 to 20.000 pH
pH Resolution 0.1, 0.01, 0.001 pH
pH Accuracy ±0.002 pH
Catalog

BOD Meter

BOD Meter NBOD-100

Measurement range 0 to 4000mg/L
Measuring error ±10%
Cycle length 5days
Catalog

BOD Meter NBOD-101

Measuring range 0 to 4000 mg/L
Measuring error ±10%
Resolution 2 mg/L
Catalog
BOD Meter NBOD-102
Measurement range 0-4000mg/L
Measuring error ±10%
Cycle length 5 days
Catalog

COD Analyzer

COD analyzer NCA-100
High COD Range 20 to 10000mg/L
Low COD Range 2 to 150mg/L
Accuracy for COD < 50mg/L ≤ ±5%
Catalog

COD Digester

Benchtop COD Digester NBCD-100

Digestion capacity 9 vials
Vial volume Maximum 10ml
Vial dimension ф16 × 100 mm
Catalog

Benchtop COD Digester NBCD-101

Digestion capacity 16 samples per run
Vial capacity 19 ml
Vial dimension Ф16×145 mm
Catalog

Conductivity Controller Analyzer

Conductivity Controller Analyzer NCCA-100
Model no NCCA-100
Measuring range k= 1 0~2000μS/cm
Resolution 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm
Catalog

Conductivity Meter (Portable)

Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.

Portable Conductivity Meter NCM-100
Conductivity specifications:- Conductivity range 0.000µS/cm ~ 1000mS/cm
Conductivity resolution 0.001µS/cm
Conductivity accuracy ± 1.0% (FS)
Catalog

Portable Conductivity Meter NCM-200

Measurement Range 0 to 400 mS/cm
Resolution 0.001 μS/cm to 0.1 mS/cm
Indication Error ±0.5% F.S
Catalog

Portable Conductivity Meter NCM-201

Conductivity range 0.000 μS/cm to 500 mS/cm
Conductivity resolution 0.001 μS/cm minimum, various range selection
Conductivity accuracy ±1.0% FS