Molecular Testing System NMTS-100 offers 16 target detection in a single sample with magnetic bead purification. This system supports rapid heating and cooling cycles to enhance reaction efficiency. It enables real-time fluorescence analysis for accurate and fast multi-gene amplification. This closed setup helps reduce contamination during both extraction and amplification steps. Our unit includes wireless connectivity and a touchscreen interface for fully independent operation.


$6,025.00

Catalog

Specifications

Sample Throughput 1 sample/Run
Multiplex 16 targets/sample
Sample Volume 500 µL
Extraction Principle Magnetic beads method
Extraction Temperature Range Room temperature to 85°C
Temperature Control Accuracy ±0.2°C
PCR Temperature Range 10 to 100 °C
PCR Max Heating/Cooling Rate 5°C/s
PCR Tube 0.2 ml transparent PCR tube
Detector SiPMT
Fluorescence Channels 4
Supported Dyes FAM, SYBR Green, VIC/JOE/HEX/TET, ROX, Texas Red, Cy5, LIZ
Excitation Wavelength 455 to 650 nm
Emission Wavelength 500 to 720 nm
Pollution Control Built-in HEPA filter and UV lamp
Operating System 7-inch touch screen
Data Transmission WiFi, Bluetooth
Power Consumption 100W
Power Supply 110 to 220V AC, 50/60Hz
Dimensions (W × D × H) 155 × 353 × 330 mm
Weight 6 Kg

Features

  • Cartridge-based workflow
  • Pre-calibrated heating block
  • Contamination control design
  • Standalone processing unit
  • Energy-efficient performance

Applications

  • Molecular Testing System NMTS-100 is designed for sensitive gene detection with reduced contamination and efficient multi-target screening. It is used in research labs, on-site testing, and distributed diagnostic centers.

Ask Expert

FAQ for Molecular Testing System NMTS-100

1: Can Molecular Testing System NMTS-100 operate in areas with limited ventilation or airflow?

Yes, Molecular Testing System runs effectively in enclosed setups such as biosafety cabinets. Labnics Molecular Testing System includes internal filtration and sealed workflow control to maintain safe operation. This allows use in environments with minimal external airflow.

2: How does the closed system design contribute to safety and reliability?

Our sealed chamber reduces exposure to aerosols and minimizes sample contamination during operation. Labnics Molecular Testing System integrates HEPA filtration and UV sterilization to support clean workflows. This setup protects both users and test results across runs.

3: Are accessories like sample tubes or cartridges replaceable or reusable?

Labnics Molecular Testing System provides approved accessories including tubes, cartridges, and filters for consistent performance. Molecular Testing System accepts both single-use and supported reusable items. Proper usage helps extend workflow efficiency and reliability.

4: How does Molecular Testing System NMTS-100 handle temperature calibration over time?

Molecular Testing System uses an internal control system to maintain thermal accuracy during each cycle. Labnics Molecular Testing System ensures consistent performance through built-in self-verification. No manual calibration is needed under standard use.

5: What display features help guide users during operation?

Our system includes a 7-inch touchscreen with clear visual steps and operational prompts. Molecular Testing System shows real-time progress and alerts throughout each stage. Users can monitor runs easily with minimal training.

6: How do Molecular Testing Systems support workflow efficiency?

Our Molecular Testing Systems streamline processes through integrated operational steps. They coordinate thermal cycling, mixing, and detection automatically. This reduces manual input and maintains process consistency.

7: Can Molecular Testing Systems minimize variability between tests?

Yes, Molecular Testing Systems are designed for controlled and repeatable processing. They maintain uniform settings across multiple runs. Consistent parameters ensure reduced test-to-test variation.

8: What kind of control is available in Molecular Testing Systems?

Labnics Molecular Testing Systems offer precise regulation of all operational stages. They manage temperature, duration, and signal capture automatically. This helps maintain reliability during repetitive procedures.

9: Do Molecular Testing Systems reduce user-dependent errors?

Molecular Testing Systems lower human error by automating key steps. They follow programmed sequences for each phase of operation. Standardization across runs improves overall process reliability.

Related Models Of Molecular Testing System

Labnics Molecular Testing Systems integrate thermal control and optical detection for simultaneous analysis of multiple genetic targets. These units allow streamlined handling of reagents, templates, and reaction mixes without user intervention. They maintain secure and uniform reaction conditions to reduce contamination risks. Their operations adapt to different throughput needs and processing requirements. Our systems ensure consistent workflows across a range of nucleic acid testing methods.

Labnics © 2025. All Rights Reserved.