Kinematic Viscometer NKV-105 has a viscosity range of 0.5 to 20,000 mm²/s for versatile fluid measurements. It utilizes advanced technology for accurate measurement of both low and high-viscosity fluids. Our unit features a high-speed thermal printer that automatically prints measurement results. This viscometer Automatically calculates kinematic viscosity and average test values. It includes a 5.7-inch LCD touchscreen display for easy operation and data visualization.
Temperature control range | Room temperature to 100°C |
Measuring range |
Kinematic viscosity: 0.5 to 20000mm²/s Dynamic viscosity: 0. 3 to 40000mPa.s |
Temperature control accuracy | 0.01℃ |
Ambient temperature | 15 to 35°C |
Ambient humidity | ˂ 85% |
Timing accuracy | ±0.1S |
Timing range | 0.1s to 999.9s |
Thermostatic bath tub | 250 × 300mm |
Printer | Low energy consumption thermal printer, paper width 55mm |
Power Supply | 220V AC ±10%50Hz±1Hz |
Kinematic Viscometer is utilized for measuring the viscosity of liquids. It finds common applications in industries such as petrochemicals, food and beverages, pharmaceuticals, and cosmetics.
Viscosity capillaries × 3
Measurement range | 25 mPa.s to 1×10000000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | (0.1, 0.2, 0.5, 1, 2, 5, 10, 20, 50, 100, 200 ) r/min |
Temperature control range | 45 to 200°C |
Measurement range | 100 mPa.s to 200000 mPa.s |
Rotors | Rotor no. 21, 27, 28, 29 ( total 4 pieces of spindles) |
Rotor speed | 5, 10, 20, 50 r/min |
Temperature control range | Room temperature to 200°C |
Speed | 0.1 to 200 infinitely variable speed, a total of 2000 speed options |
Measuring Range | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Rotor 1 – 4</td> <td style=min-width:50px>10 to 6 M mPa. s</td> </tr> <tr> <td style=min-width:50px>ULR</td> <td style=min-width:50px>1 to 6 K</td> </tr> <tr> <td style=min-width:50px>Rotor 18</td> <td style=min-width:50px>1.5 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 25</td> <td style=min-width:50px>240 to 4.8 M</td> </tr> <tr> <td style=min-width:50px>Rotor 31</td> <td style=min-width:50px>15 to 300 K</td> </tr> <tr> <td style=min-width:50px>Rotor 34</td> <td style=min-width:50px>30 to 600 K</td> </tr> </table> |
Display Mode | 5-inch color touchscreen |
Rotor | L1 – L4 (Standard); Enhanced Ultra – low Viscosity adapter ULR (optional); Small sample adapters (rotors 18, 25, 31, 34) (optional) |
Measuring range | 0.1 to 2,000,000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 100000 mPa.s |
Rotating speed | 3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±0.5% |
Measuring range | 1 to 200000 mPa.s |
Rotating speed | 0.3/0.6/1.5/3.6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Measuring range | 1 to 600000 mPa.s |
Rotating speed | 0.1/0.3/0.6/1.5/3/6/12/30/60 (r/min) |
Rotor | 1-4 number rotors, Measuring viscosity lower than 10 needs to be equipped with the 0 number rotar |
Measuring Error (Newtonian liquid) | ±1% |
Temperature control range | Room temperature + 5 ℃ to 100 ℃ |
Temperature control accuracy | ± 0.01 ℃ |
Time accuracy | ± 0.01% (not greater than ± 0.01% for 60 minutes) |
Viscosity range | 0.3 to 5000 mm²/s |
Temperature Range | -70℃ to 135℃. |
Accuracy | ±0.1℃ |
Ambient Temperature | 5℃ to 40℃; |
Ambient Humidity | <85% |
Temperature control range | Room temperature to 120 °C can be adjusted |
Temperature control accuracy | ± 0.05 ° C |
Ambient temperature | 5 to 40 ° C |
Ambient Humidity | < 85%RH |