Karl Fischer Titrator NKFT-100
Karl Fischer Titrator - NKFT-100 is a volumetric type auto analyzing titrator that helps to determine the moisture content of a sample. It is an enclosed automated system with a reagent bottle adaptor and an endpoint detector that sets it free from environmental interference. The functions like solvent inhalation, determination, wastewater discharge, can easily be operated by its panel keys. The electrode polarization voltage aids in determining the end of the titration process with an alarm sound.
Measuring range | 0.02% -100% |
Moisture Resolution | 0.01ml |
Moisture titration Repeatability | ≤ 0.01 |
Moisture titration linear correlation coefficient | ≥ 0.998 |
Capacity error | ≤ ± 0.002 |
Relative error | ≤ 0.2 % |
Burette capacity | >25ml |
Sensitivity | 10 -6 ml |
Dimensions | 360 × 370 × 380 mm |
Weight | 11 kg |
It is widely used for the determination of traces of water in industrially produced products that should have aw limits. It finds its applications in chemistry, research and development, pharmaceutical industries, petroleum and oil testing laboratories and food development and technology etc.
Accessories No | Name |
1 | Host |
2 | Reaction cup |
3 | 2pc Stirrer |
4 | 2pc Glass burette |
5 | Mounting bracket |
6 | Double platinum electrode |
7 | Silicone feeding plug |
8 | Silicone titration Plug |
9 | Power line |
10 | 3pc Fuse |
Accessories No | Name |
1 | 500 ml waste water bottle |
2 | Karl Fischer Reagent |
3 | 10 µl Microsyringe |
Labnics Karl Fischer Titrators are designed for precise moisture content analysis. They feature enclosed systems to prevent environmental interference. They come with user-friendly panel keys for easy operation of various functions. These titrators are equipped with LCDs that display critical parameters like moisture content and titration curves. Our units offer resettable programs, providing flexibility during the titration process.
Labnics Automatic Potentiometric Titrator supports multiple titration methods for versatile applications. They are equipped with high-accuracy burettes that ensure precise and consistent delivery of titrants. These titrators feature data analysis capabilities, enabling efficient review of results. They offer data storage with GLP-compliant features for improved traceability and record-keeping. Our units are equipped with an integrated stirrer to ensure uniform mixing.
Measuring Range | (-1999.0~1999.0) mv; (0.00~14.00) pH |
Measuring Resolution | 0.1mV; 0.01pH |
Measuring Accuracy | pH: ± 0.01 pH; mv: ±0.03% FS |
Measuring Fluctuation | (± 0.3mV ±1bit) /3h |
Measuring Range | ± 1400 mV; (0.00~14.00) pH |
Measuring Resolution | 1 mV; 0.01pH |
Measuring Accuracy | mv: ± 5mV ; pH: ± 0.03 pH ±1 digit |
Stability | ± 0.01 pH/3h |
Measuring Range | (-1999.0~1999.0) mv; (0.00~14.00) pH |
Measuring Resolution | 0.1mV; 0.01pH |
Measuring Accuracy | pH: ± 0.01 pH; mv: ±0.03% FS |
Measuring Fluctuation | (± 0.3mV ±1bit) /3h |
Measuring Range | (-1999.0~1999.0) mv; (0.00~14.00) pH |
Measuring Resolution | 0.1mV; 0.01pH |
Measuring Accuracy | pH: ± 0.01 pH; mv: ±0.03% FS |
Measuring Fluctuation | (± 0.3mV ±1bit) /3h |
Measring unit | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range</td> <td style=min-width:50px>(-1999.0 to -1.999.0) mV</td> </tr> <tr> <td style=min-width:50px>Resolutions</td> <td style=min-width:50px>0.1mv, 0.01 pH</td> </tr> <tr> <td style=min-width:50px>Accuracy</td> <td style=min-width:50px>Ph ± 0.01Ph, mv ±0.03%FS</td> </tr> <tr> <td style=min-width:50px>Fluctuations</td> <td style=min-width:50px>(±0.3mV± 1bit)</td> </tr> </table> |
Temperature compensation | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range</td> <td style=min-width:50px>(-5.0 to 105.0) °C</td> </tr> <tr> <td style=min-width:50px>Resolutions</td> <td style=min-width:50px>0.1 °C</td> </tr> <tr> <td style=min-width:50px>Accuracy</td> <td style=min-width:50px>±0.3 °C</td> </tr> </table> |
Mechanical unit | Resolution 1/30000 |
Burette | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Titrimetric repeatability</td> <td style=min-width:50px>0.20%</td> </tr> <tr> <td style=min-width:50px>Accuracy</td> <td style=min-width:50px>10 ml burette: ± 0.025ml 20 ml burette: ± 0.025ml</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>10 ml burette: ± 0.035µl 20 ml burette: ± 0.66µl </td> </tr> </table> |