WhatsApp
Horizontal Shaker Incubator NHSI-104

Horizontal Shaker Incubator NHSI-104

Horizontal Shaker Incubator NHSI-104 features a temperature range of 4 to 60°C and a spacious 280 L capacity. It has a touchscreen that displays real-time parameters for clear monitoring. Our unit includes a reservation function for scheduled operations with secure access control. It is equipped with tempered glass doors for enhanced visibility and reliable protection. This incubator offers customizable multi-segment cycles for precise regulation.


$6,387.00

Data Sheet

Specifications

Capacity 280 L
Temperature Range 4 to 60°C
Temperature Resolution 0.1°C
Temperature Fluctuation ±0.3°C
Temperature Uniformity ±1°C
Humidity Range Ambient Humidity -95% RH
Humidity Fluctuation ±3%
Rotation Rate 30 to 300 RPM
Rotation Accuracy ±1 RPM
Vibration Amplitude Ø26 mm
Timer Range 0 to 999 min/h
Tray Size 950 × 530 mm
Standard Configuration 2000 ml × 6
Full Load Configuration 50 ml × 71
100 ml × 71
250 ml × 45
500 ml × 37
1000 ml × 18
2000 ml × 15
3000 ml × 8
5000 ml × 7
Power Consumption 2400 W
Internal Dimensions 1010 × 590 × 470 mm
External Dimensions 1380 × 700 × 1000 mm
Package Dimensions 1410 × 910 × 1200 mm
Net Weight 266 kg
Gross Weight 328 kg

Features

Secure mechanical door lock

Integrated water tank

Powerful DC motor

USB storage

High-quality compressor

Applications

Horizontal Shaker Incubator NHSI-104 is suitable for microbial cultivation, cell growth, and biochemical research requiring precise control of temperature, humidity, and shaking.

Ask Expert

FAQ for Horizontal Shaker Incubator NHSI-104

1: What event recording features are available on the Horizontal Shaker Incubator?

The Horizontal Shaker Incubator comes with an event recording function, enabling you to track and review operational data, curves, and other critical performance metrics.

2: How can I ensure safe and optimal performance of the Horizontal Shaker Incubator?

To maintain the Horizontal Shaker Incubator's performance, regularly clean the interior, monitor humidity levels, and ensure that the doors are securely locked during operation.

3: How does the humidity control system work in the Horizontal Shaker Incubator NHSI-104?

The Horizontal Shaker Incubator features a humidity control system with an integrated water tank, ensuring stable moisture levels for sensitive samples during incubation.

4: How do I clean and maintain the Horizontal Shaker Incubator?

To maintain the horizontal shaker incubator, wipe the interior with a non-abrasive cloth and mild detergent. Avoid moisture in electrical components and inspect seals and doors for wear.

5: Can I use the Horizontal Shaker Incubator NHSI-104 for overnight experiments?

Yes, the Horizontal Shaker Incubator supports overnight or long-duration experiments with its programmable and reservation features, ensuring reliable performance without constant monitoring.

6: What is the purpose of the reservation function and permission levels in the Horizontal Shaker Incubator?

The reservation function lets users schedule incubation cycles in advance, optimizing lab time and workflow. Multi-level permission access adds a layer of operational security by restricting control based on user roles, preventing unauthorized adjustments and protecting experiment integrity.

7: What advantages do the high-quality compressor and DC motor provide in the Horizontal Shaker Incubator?

The integrated high-quality compressor ensures efficient temperature regulation, while the DC motor delivers stable and quiet shaking performance. These components work together to maintain precise incubation conditions, reduce noise in the lab, and extend the overall lifespan of the equipment.

8: How is data stored and exported from the Horizontal Shaker Incubator?

This incubator can store up to one million data records internally and offers a USB storage function for easy data export. This feature allows users to archive experiment logs, transfer data for analysis, or meet documentation requirements without disrupting operations.

9: How should I maintain the Horizontal Shaker Incubator for optimal performance?

Regularly clean the interior chamber, shaking platform, and tempered glass doors to prevent contamination. Inspect mechanical components such as the motor and compressor for dust accumulation, and check seals and locks for signs of wear to ensure proper sealing of the chamber. Additionally, avoid overloading the shaker to prevent undue strain on mechanical components and ensure reliable and consistent operation.

Related Models Of Horizontal Shaker Incubator

Labnics Horizontal Shaker Incubators offer adjustable shaking speed for controlled and efficient sample agitation. They include a digital control panel for easy and precise adjustment of settings. These units are equipped with low-noise motors to ensure quiet and stable operation. They provide over-temperature protection and alarm alerts for enhanced safety. Our horizontal shaker incubators are designed with sturdy construction for long-lasting performance and reliability.

Labnics © 2026. All Rights Reserved.
0