Vertical Autoclave NVA-200 is a laboratory sterilization system that uses pressurized steam at 121–134°C to eliminate microorganisms, spores, and contaminants from instruments, glassware, culture media, and biohazardous waste. It supports both gravity and pre-vacuum cycles for consistent and controlled sterilization.
Vertical Autoclave NVA-200 provides accurate steam sterilization for laboratories and clinical environments, combining 50–200 L capacity, gravity and pre-vacuum cycles, and digital control for precise and compliant sterilization processes.
Sterilization of laboratory instruments and glassware
Preparation of microbiological culture media
Decontamination of biohazardous waste
Routine sterilization in clinical and research labs
Water is heated to produce saturated steam
Steam fills the sealed chamber
Air is removed (gravity or pre-vacuum)
Pressure and temperature increase
Microorganisms and spores are destroyed
Chamber cools and depressurizes safely
Higher temperature ensures faster sterilization.
Steam sterilization uses high-pressure saturated steam to destroy microorganisms by denaturing proteins and disrupting cellular structures.
Gravity Cycle
Steam displaces air naturally
Suitable for glassware and solid instruments
Pre-Vacuum Cycle
Air is actively removed using vacuum
Ideal for porous loads and complex instruments
Pharmaceutical and biotech laboratories
Hospitals and clinical sterilization units
Research and academic institutions
Quality control and testing laboratories
Gravity and pre-vacuum sterilization cycles
Digital monitoring and control system
Adjustable time and temperature settings
Safety interlocks and pressure protection
Vertical space-saving design
This model is ideal for:
Laboratories needing flexible capacity (50–200 L)
Facilities requiring both gravity and pre-vacuum cycles
Hospitals with mixed sterilization loads
Labs requiring precision-controlled sterilization workflows
Answer:
Choose NVA-200 if you need a balance of capacity, flexibility, and space efficiency.
Glassware, instruments, culture media, and biohazardous waste.
Typically 15–60 minutes, depending on load and cycle.
Yes, liquids can be safely sterilized with controlled heating and cooling.
Between 121°C and 134°C.
High-pressure steam destroys microorganisms by denaturing proteins and damaging cell structures.
Gravity uses natural air displacement, while pre-vacuum removes air actively for deeper penetration.
Laboratory instrument sterilization
Media preparation
Waste decontamination
Clinical sterilization workflows
USP sterilization guidelines
ISO 17665
Laboratory safety standards
Vertical Autoclave NVA-200 is a versatile laboratory steam sterilization system supporting 50–200 L capacity with gravity and pre-vacuum cycles. Operating at 121–134°C, it ensures effective microbial elimination, supports regulatory compliance, and provides flexible sterilization for laboratory, clinical, and research applications.