WhatsApp

Air Shower NAS-205 – Cleanroom Entry Contamination Control Equipment


What is Air Shower NAS-205?

Air Shower NAS-205 is a controlled entry contamination removal system used in cleanrooms to eliminate dust and particles from personnel and materials before entry.

It acts as a physical contamination barrier between non-clean and clean environments.


Why is it Important? 

Air showers are essential because:

  • Humans continuously carry dust, fibers, and particles

  • Even microscopic contamination can damage sensitive production

  • Semiconductor and pharmaceutical environments require ultra-clean conditions

Without air showers:

  • Product rejection rates increase

  • Batch contamination risk rises

  • Regulatory compliance failures may occur

  • Production downtime increases


What is it Used For? 

Air Shower NAS-205 is used for:

  • Cleanroom entry contamination removal

  • Personnel decontamination before gowning

  • Material transfer cleaning

  • Sterile environment protection

  • ISO-classified cleanroom compliance support


How Does Air Shower NAS-205 Work? 

  1. Personnel or materials enter chamber

  2. Interlocking doors seal entry zone

  3. HEPA-filtered air jets activate

  4. High-speed airflow dislodges particles

  5. Contaminants are captured by return filtration system

  6. Cleaned personnel/material exits into cleanroom


Core Functional Capabilities

  • High-velocity HEPA-filtered air jets

  • Multi-directional nozzle system

  • Interlocked safety door system

  • Stainless steel cleanroom-grade construction

  • Adjustable cycle control (30–60 sec)

  • Low-turbulence airflow design


Technical Specifications

Parameter

Specification

Air Velocity

20–30 m/s

Filtration

HEPA (99.97% @ 0.3 µm)

Cycle Time

30–60 seconds

Construction

Stainless steel / powder-coated steel

Power Supply

220 V AC, 50 Hz


Where is Air Shower NAS-205 Used?

  • Pharmaceutical cleanrooms

  • Biotechnology laboratories

  • Healthcare sterile zones

  • Semiconductor fabrication units

  • Food processing facilities

  • Electronics manufacturing plants


When Should You Use Air Shower NAS-205?

Use Air Shower NAS-205 when:

  • Cleanroom contamination risk is high

  • Personnel or materials enter sterile environments

  • ISO 14644 compliance is mandatory

  • GMP/FDA regulated production is required

  • Particle-free environment is critical for quality


Air Shower vs Alternatives 

Equipment

Best Used When

Air Shower NAS-205

Personnel/material contamination removal needed

Pass Box

Only material transfer is required

Airlock

Pressure control between cleanroom zones is needed

Choose based on function, not structure


Compliance Explained 

  • ISO 14644 → Defines maximum airborne particle limits in cleanrooms

  • GMP → Ensures controlled, repeatable, contamination-free manufacturing

  • FDA Guidelines → Ensures pharmaceutical safety and regulatory approval

Without compliance, product quality and regulatory approval are at risk.


Frequently Asked Questions 

1.What is Air Shower NAS-205 used for?
  It removes particulate contamination before cleanroom entry.

2.How does an air shower work?
  It uses HEPA-filtered high-velocity air to dislodge and capture particles.

3.What is air velocity in Air Shower NAS-205?
  Typically 20–30 m/s.

4.What filtration is used?
  HEPA filtration system.

5.How long is the cycle time?
  30–60 seconds depending on protocol.

6.Is it mandatory in cleanrooms?
  Not mandatory, but widely used in controlled environments.

7.Can it reduce microbial contamination?
  Yes, indirectly by removing particle carriers.


Quick Summary 

Air Shower NAS-205 is a cleanroom entry contamination control system designed to remove dust, fibers, and airborne particles from personnel and materials before they enter controlled environments. It uses high-velocity HEPA-filtered air jets (20–30 m/s) to dislodge contaminants and capture them through a recirculating filtration system within a 30–60 second cycle.

Labnics © 2026. All Rights Reserved.