Let's Chat

Any Query ?

Portable Fluoride Analyzer NPFA-100

Portable Fluoride Analyzer NPFA-100

Portable Fluoride Analyzer NPFA-100

Portable Fluoride Analyzer NPFA-100 is designed with an auto-read function and is suitable for outdoor applications. In addition to a backlit LCD display, automatic electrode diagnosis, 2 to 5 calibration points, and automatic temperature compensation, this device also has a calibration-due alarm system. The unit has USB interface for data processing and transfer and setup menu to set up number of calibration points, stability criteria, temperature unit, date and time etc.

Specifications

Ion Concentration
Range 0.02 to 1900 ppm
Resolution 0.001, 0.01, 0.1, 1, automatic
Accuracy ±0.5% F.S
Calibration Points 2 to 5 points
Calibration Solutions 0.001 / 0.01 / 0.1 / 1 / 10 / 100 /1000/10000
Measurements Units ppm, mg/L, mol/L, mmol/L
mV
Range (-1999.9 to 1999.9) mV
Resolution 0.1 mV
Accuracy ±0.2 mV
Temperature
Range 0 to 105°C / 32 to 221°F
Resolution 0.1°C/°F
Accuracy ±0.5°C / ±0.9°F
Offset Calibration 1 point
Calibration Range Reading ±10°C/°F
Other
Temperature Compensation 0 to 100°C / 32 to 212°F, manual or automatic
Hold Function Manual / Auto-read measurement endpoint
Stability Criteria Low / High
Calibration Due Alarm 1 to 31 days or off
Auto-Power Off 10 / 20 / 30 minutes after last key pressed
Memory Stores up to 500 data sets
Output USB communication interface
Connector BNC, 3.5 mm jack socket
Display Custom LCD (80 × 60 mm)
Power Supply 3 × 1.5V AA batteries or 5V DC power adapter
Battery Life Approximately 150 hours without backlight
Environmental Conditions 0 to 50°C / 32 to 122°F, relative humidity < 80%
Dimensions 170 × 85 × 30 mm
Weight 300g

Features

  • Large backlit LCD display
  • 2 to 5 points calibration from low to high concentrations
  • Selectable 8 concentration calibration points, including the 0.001 to 10000
  • Selectable concentration units - ppm, mg/L and m
  • Automatic temperature compensation ensures accurate readings over the entire range
  • Automatic electrode diagnosis shows the calibration points and slopes
  • Auto-Read function senses and locks the measurement endpoint
  • Calibration due alarm prompts user to calibrate the meter regularly
  • Auto-Power Off effectively conserves battery life
  • Setup menu allows setting the number of calibration points, stability criteria, temperature unit, date and time, etc
  • Reset function automatically resumes all settings back to the factory defaults
  • Expanded memory stores or recalls up to 500 data sets
  • USB communication interface for data transfer or connecting a power adapter to meter

Applications

Portable Fluoride Analyzer NPFA-100 is used to monitor levels of fluoride in water in food & beverage industries, water & wastewater treatment plants, pharmaceutical industries, chemicals & petrochemicals, etc.

Get Quote