Dissolved Oxygen Sensor NOS-100 is a compact, handheld sensor that help in easy and accurate dissolved oxygen measurement. Designed with economical but durable stainless-steel probe, these sensors are suitable for portable as well bench top use. Equipped with automatic as well as manual mode, it is the ultimate water quality field instrument for sampling and profiling of water samples. This sensor is widely applied in many water quality applications, such as aquaculture, environment monitoring, and natural sciences.
Specifications
Dissolved Oxygen Range | 0~20 mg/L or 0~200 % |
Dissolved Oxygen Sensor | Optical DO sensor |
Dissolved Oxygen Accuracy | 0.01 |
Dissolved Oxygen Sensor Drift | <1 % per year |
Sensor Material | SS316 / Titanium alloy |
Temperature Range | 0 °C ~ 40 ℃ |
Temperature Accuracy | ± 0.2 °C |
Measuring Distance | 3 meters ~5 meters |
Working Temperature | -20 ℃ ~ 50 ℃ |
Power Supply | 3V ~ 6V |
Power Consumption | < 0.5 Watts |
Signal Output | RS-485 |
Battery Requirement | 9 V |
Features
Applications
Ask Expert
Dissolved Oxygen Range | 0 to 20mg/L or 0 to 200% |
Sensor | Optical DO sensor |
DO Accuracy | 0.03 |
Measurement range | 0 to 4000mg/L |
Measuring error | ±10% |
Cycle length | 5days |
Measuring range | 0 to 4000 mg/L |
Measuring error | ±10% |
Resolution | 2 mg/L |
Measurement range | 0-4000mg/L |
Measuring error | ±10% |
Cycle length | 5 days |
High COD Range | 20 to 10000mg/L |
Low COD Range | 2 to 150mg/L |
Accuracy for COD < 50mg/L | ≤ ±5% |
Digestion capacity | 9 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 100 mm |
Digestion capacity | 16 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 150 mm / ф20mm × 150 mm |
Model no | NCCA-100 |
Measuring range | k= 1 0~2000μS/cm |
Resolution | 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm |
Labnics Portable Conductivity Meters provide accurate and reliable conductivity measurements for various applications. They feature automatic and manual temperature compensation for accurate readings. These units offer data storage and USB transfer for efficient record management. They come with a high-brightness backlit display for clear visibility in any environment. These meters have an auto power-off function to conserve battery life and extend usage time.
Conductivity specifications:- Conductivity range | 0.000µS/cm ~ 1000mS/cm |
Conductivity resolution | 0.001µS/cm |
Conductivity accuracy | ± 1.0% (FS) |
Measurement Range | 0 to 400 mS/cm |
Resolution | 0.001 μS/cm to 0.1 mS/cm |
Indication Error | ±0.5% F.S |
Conductivity range | 0.000 μS/cm to 500 mS/cm |
Conductivity resolution | 0.001 μS/cm minimum, various range selection |
Conductivity accuracy | ±1.0% FS |