Any Query ?
Digital PH Meter NDPM-100
Digital pH Meter NDPM-100 provides a pH range of 0.00 to 14.00 with an accuracy of ± 0.01 pH for reliable results. It includes automatic and manual temperature compensation modes, ensuring accurate readings across varying temperatures. This meter is equipped with a lead-in wire that must remain constant to avoid measurement errors. Our pH meter incorporates a white backlight, displaying pH and potential values (mV) for detailed measurements.
pH Range | 0.00 to 14.00 pH |
pH Accuracy | ± 0.01 pH |
pH Resolution | 0.01 pH |
Calibration Points | Three points (4.00, 6.86, 9.18) |
Calibration Solutions | Potassium Hydrogen Phthalate, Phosphate Mixture, Borax |
Temperature Range | 0° to 60° C |
Temperature Accuracy | ± 1° C |
Temperature Resolution | 1° C |
Automatic Temperature Compensation | 0° to 60° C |
ORP Range | ± 1999 mV |
ORP Accuracy | ± n × 0.1% ± 1 (n: Displayed no.) mV |
ORP Resolution | 1 mV |
Ambient Temperature | 0° to 40° C |
Relative Humidity | < 85% |
Input Resistance | ≥ 1 × 10¹² Ω |
Zero Drift | ≤ 0.01 pH ± 1 per 2 hours |
Power | 2W |
Dimension | 180 × 80 × 30 mm |
Weight | 0.5 kg |
Digital pH Meter measures pH and potential values (mV) for electrochemical analysis in industries, research, and environmental monitoring, supporting quality control, laboratories, and scientific studies.
Plastic body pH electrode × 1
Battery × 4 pcs
Measurement range | 0-4000mg/L |
Measuring error | ±10% |
Cycle length | 5 days |
Measure amount | 6 |
Measuring range | 0 to 4000 mg/L |
Measuring error | ±10% |
Resolution | 2 mg/L |
Cycle length | 1-5 days |
Measurement range | 0 to 4000mg/L |
Measuring error | ±10% |
Cycle length | 5days |
Measure amount | 6 |
High COD Range | 20 to 10000mg/L |
Low COD Range | 2 to 150mg/L |
Accuracy for COD < 50mg/L | ≤ ±5% |
Accuracy for COD > 50mg/L | ≤ ±3% |
Digestion capacity | 9 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 100 mm |
Digestion temperature | 20°C - 200°C |
Digestion capacity | 16 vials |
Vial volume | Maximum 10ml |
Vial dimension | ф16 × 150 mm / ф20mm × 150 mm |
Digestion temperature | 45°C - 190°C |
Model no | NCCA-100 |
Measuring range | k= 1 0~2000μS/cm |
Resolution | 0.01μS/cm , 0.1μS/cm , 1μS/cm , 0.01mS/cm 0.1mS/cm |
Accuracy | ± 2.0 %(FS) |
Conductivity specifications:- Conductivity range | 0.000µS/cm ~ 1000mS/cm |
Conductivity resolution | 0.001µS/cm |
Conductivity accuracy | ± 1.0% (FS) |
Resistivity specifications:- Resistivity range | 5.00Ωcm~ 100.0MΩcm |
Dissolved Oxygen Range | 0.00-20.00mg/L |
Dissolved Accuracy | ±0.2mg/L |
Dissolved Resolution | 0.01 mg/L |
Saturation of Oxygen Range | 0.0-200.0% |
Dissolved Oxygen Range | 0~20 mg/L or 0~200 % |
Dissolved Oxygen Sensor | Optical DO sensor |
Dissolved Oxygen Accuracy | 0.01 |
Dissolved Oxygen Sensor Drift | <1 % per year |
Dissolved Oxygen Range | 0 to 20mg/L or 0 to 200% |
Sensor | Optical DO sensor |
DO Accuracy | 0.03 |
Dissolved Oxygen Sensor | Drift <1% per year |
Ion Concentration |
|
||||||||||||||||||||||||||||
mV |
|
||||||||||||||||||||||||||||
Temperature |
|
||||||||||||||||||||||||||||
Other |
|
Labnics Benchtop Multi-Parameter Meter offers both automatic and manual temperature compensation, ensuring precise measurements. They include data analysis functions for detailed examination and interpretation of results. Our units include a touchscreen for simple and intuitive operation. These meters feature automatic electrode diagnosis to continuously monitor electrode conditions. They offer a data storage function for saving and managing measurement records.
pH Specifications:- Range | (-2.000~20.000) pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH, Selectable |
Calibration Points | 1 to 5 points |
pH Specifications:- Range | (-2.000~20.000) pH |
pH Accuracy | ±0.002pH |
pH Resolution | 0.1, 0.01, 0.001pH, Selectable |
pH Calibration Points | 1 to 5 points |
Test Parameters | pH/EC/ISE/DO/Temp. (mV/ORP/pX/Resistivity/TDS/Sal. /DO Saturation) |
pH | Range: -2.000 to 20.000 pH<br/> Resolution: 0.1, 0.01, 0.001 pH<br/> Accuracy: ±0.002 pH<br/> Calibration Points: Up to 6<br/> Standard Customization: Yes<br/> Calibration Reminder: Yes<br/> Slope Limit: Yes |
Calibration Solutions | NIST, GB, DIN, USA, MERK, JIS buffers |
mV/ORP | Range: -2000.00 to 2000.00 mV<br/> Resolution: 0.1, 0.01 mV<br/> Accuracy: reading whichever is greater<br/> Calibration Points: 1 custom point (relative mV) <br/> EH ORP Mode: Yes |
Labnics Multiparameter Conductivity Meter are designed to measure multiple parameters for comprehensive analysis. They feature imported sensors and advanced optical system for precise measurement. They offer various conductivity ranges for accurate sample readings. They are constructed with durable materials to withstand harsh environments. Our meter is ideal for water quality analysis, environmental monitoring and industrial processes.
pH |
|
||||||||||||||||||
mV |
|
||||||||||||||||||
Conductivity |
|
||||||||||||||||||
TDS |
|
Absorbance Detection Range | 0 to 3Abs |
Absorbance Resolution | 0.001Abs |
Optical Path Stability | ≤ ±0.005Abs/30min |
Operation Repeatability | ≤ ±0.01Abs |
pH Range | 2.000~20.000 pH |
pH Accuracy | ±0.002pH |
pH Resolution | 0.1, 0.01, 0.001pH, selectable |
Calibration Points | 1 to 5 points |
Model no | NPCA-100 |
Detection method | Electrode method |
Measuring range | 0 ~ 14 pH; normal temperature (0 ~ 80 ℃) |
Resolution | 0.01ph |
pH measuring range | 0.00 ~ 14.00 pH |
pH resolution | 0.01 pH |
pH accuracy | ± 0.01 pH |
Temperature measuring range | 0°C~100°C |
pH Specifications:- Range | (-2.000~20.000) pH |
Accuracy | ±0.002pH |
Resolution | 0.1, 0.01, 0.001pH, Selectable |
Calibration Points | 1 to 5 points |
Model name | NPOM-100 |
Measuring Range | -2.00~20.00pH |
Display Resolution | 0.01pH |
Measurement Accuracy | ± 0.01pH |
Measurement range | 0~1100 NTU, 0~275 EBC, 0~9999 ASBC |
Measurement accuracy | ±2% of reading (0~500 NTU), ±3% (501~1100 NTU) |
Measurement resolution | 0.01 (0~100 NTU), 0.1 (100~999 NTU), 1 (999~1100 NTU) |
Sample volume | 30 ml |
Parameters | Conductivity, Temperature, Resistivity, TDS, and Salinity |
Conductivity mode | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 µS/cm to 3000 mS/cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 µS/cm minimum, changes with ranges</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>± 0.5% FS</td> </tr> <tr> <td style=min-width:50px>Reference Temperature </td> <td style=min-width:50px>5, 10, 15, 18, 20, 25 ºC</td> </tr> <tr> <td style=min-width:50px>Calibration Points </td> <td style=min-width:50px>Up to 5</td> </tr> <tr> <td style=min-width:50px>Standard Recognition </td> <td style=min-width:50px>146.5 µS/cm, 1408 µS/cm, 12.85 mS/cm, 111.3 mS/cm</td> </tr> </table> |
Resistivity Mode | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>5.00 Ω ·cm to 100.00 M Ω ·cm</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.01 Ω ·cm minimum</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px> ± 0.5% FS</td> </tr> </table> |
TDS Mode | <table cellspacing=0 border=1> <tr> <td style=min-width:50px>Range </td> <td style=min-width:50px>0.000 mg/L to 1000 g/L</td> </tr> <tr> <td style=min-width:50px>Resolution </td> <td style=min-width:50px>0.001 ppm minimum, changes with range</td> </tr> <tr> <td style=min-width:50px>Accuracy </td> <td style=min-width:50px>±0.5% FS</td> </tr> </table> |
pH Range | (-1.00) to 15.00 |
pH Accuracy | ±0.01 |
pH Calibration Points | 1 to 3 points |
pH Buffer Options | pH 4.01/6.86/7.00/9.18/10.01 |
COD Measurement Range | 0-15000mg/L |
Ammonia Nitrogen Measurement Range | 0-160mg/L |
Phosphorus Measurement Range | 0-100mg/L |
Nitrogen Measurement Range | 0-150mg/L |
Measurement Range | 0 to 35500mg/L(ppm) |
Measurement Principle | Ion electrode method |
Resolution | 0.01mg/L(ppm) |
Basic Error | ± 2.5% |
Labnics Online Ozone Meter detects ozone levels accurately across a wide range of concentrations. They include manual and automatic temperature compensation modes for reliable results. These ozone meter comes with built-in alarm functions for immediate alerts on fluctuating values. They enable efficient and reliable data transfer, ensuring smooth integration with other systems. Our units feature a large screen display for clear and easy interpretation of results.
Measurement Range | 0 to 20mg/L<br/> 0 to 20 ppm |
Measurement Principle | Potentiometric method |
Resolution | 0.001mg/L;0.001ppm |
Basic Error | ±1%F. S |