WhatsApp

Headspace Gas Chromatography NHGC-100 Data Sheet

Laboratory Equipment
Product Series / Headspace Gas Chromatography
Headspace Gas Chromatography
NHGC-100
Double cooling position design Sample cooling
Room temperature +5℃ to 300℃ Temperature setting range
Room temperature +5℃ to 300℃ Transmission line temperature range
Headspace Gas Chromatography NHGC-100
Labnics Product Data Sheet · Laboratory Equipment
Headspace Gas Chromatography

Headspace Gas Chromatography NHGC-100

Headspace Gas Chromatography NHGC-100   handles 75 samples with dual trays and overlapping heating for higher throughput . It has a five-level vibration heating system to speed up the gas-liquid balance. This system uses static headspace pressurization for solvent-free, efficient extraction and holds up to 3 capillary columns. It features a fully inert flow path and supports operation up to 300°C, ensuring high sensitivity. Our Gas Chromatography has precision EPC control that delivers excellent reproducibility and wide compatibility​.

Key metrics
Double cooling position design
Sample cooling
Room temperature +5℃ to 300℃
Temperature setting range
Room temperature +5℃ to 300℃
Transmission line temperature range
Headspace Gas Chromatography NHGC-100
Labnics Ltd.

Specifications

Sample cooling Double cooling position design
Temperature setting range Room temperature +5℃ to 300℃
Transmission line temperature range Room temperature +5℃ to 300℃
Valve box temperature range Room temperature +5℃ to 300℃
Operating ambient temperature 5°C to 35°C.
Operating ambient humidity 5% to 95%.
Priority position 3 positions
Pressure control EPC control
Quantitative volume 0.1mL, 0.5mL, 1mL and 3mL for option
Calibration function With an automatic calibration function
Leak detection mode Automatic leak detection
Automation form XYZ three-coordinate form
System function Instrument alarm, maintenance log, etc.
Auxiliary function 5-stage sample oscillation function/overlapping heating/multiple extractions
Repeatability 1.5% RSD
Transmission line Connected with GC injection port to realize tool-free quick disassembly and 360° protection sleeve
Valve Support Supports installation of up to 6 valves
Temperature range of column oven +4°C to 450°C
Temperature setting accuracy of the column oven ≤0.1°C.
Maximum heating rate of the column oven ≥120°C/min
Maximum running time 999.99 min.
Supporting simultaneous installation for GC Two injection ports Four detectors Three detector signals
Column oven Dimension 28x31x16 cm
Gas type Nitrogen/Helium
Communication mode LAN
Power Consumption ≤800W
Dimension (L × W × H) 558 × 556.4 × 486 mm
GC Packaging Dimension 1 810 × 720 × 910 mm
GC Packaging Dimension 2 320 × 450 × 330 mm
Headspace Packaging Dimension 1 810 × 720 × 910 mm
Headspace Packaging Dimension 2 800 × 480 × 500 mm
Net Weight for GC 38.1 kg
Gross Weight for GC 140 kg
Gross Weight for Headspace 43kgs
Headspace Gas Chromatography NHGC-100 · Product Details

Optional Accessories

Gas chromatograph Optional part- 

Inlet:

  • Inert split/splitless inlet × 2 pc

  • Split/splitless inlet maintenance tool × 1 pc

  • Inlet consumables × 1 pc

  • One-to-two flow splitter assembly (excluding chromatographic column and sealing ring) × 1 pc

Detector:

  • Hydrogen Flame Ionization Detector (FID) × 2 pc

Auxiliary Equipment:

  • Network switch (Required when ordering autosampler) × 1 pc

  • Hydrogen generator (Maximum flow rate 500mL/min) × 1 pc

  • Air Generator (Maximum flow rate 2000ml/min) × 1 pc

Headspace Autosampler (75-position) Optional part- 

  • Lid lifter × 1 pc

  • Sample transfer line (1.5m/stick) × 1 stick

Standard Accessories

Gas chromatograph standard part- 

  • GC installation accessories kit (include:1/8 inch copper pipe × 50ft/roll, 1/8 inch Brass Compression Fitting Nuts, 1/8 inch Brass front and rear ferrule components, Brass Tee) 

  • GC installation tool kit 

Headspace Autosampler (75-position) standard part- 

  • Headspace Autosampler (75-position), including sample transfer line 1m × 1 set

  • Toolkit (only used for Headspace Autosampler) × 1 set

  • Engineering installation package (only used for Headspace Autosampler) × 1 set

  • Polyimide gasket ring (0.53 mm): 5pcs /pack × 1 pack

  • 20mL flat bottom headspace vial (flat bottom crimp top): 100pcs /pack × 1 pack

  • Headspace aluminum crimp top caps with PTFE septa: 100pcs /pack × 1 pack

  • 0.53µm quartz tube (5m) × 1 stick

  • Headspace Autosampler GC installation package × 1 set

  • Acceptance package × 1 set

Features

  • Multiple extraction/injection
  • Solvent-free sampling
  • Self-calibration function
  • Tool-free quick connect
  • Overlapping heating
  • Automatic leak detection
  • Color touch screen interface
  • Electronic gas circuit control

Applications

Headspace Gas Chromatography NHGC-100 is used for rapid, solvent-free analysis of volatile compounds from liquid and solid samples. It is widely applied in food safety, forensics, pharmaceuticals, and material science for accurate testing​.

Optional Consumables

Gas chromatograph Consumables:

  • Universal water, oxygen and hydrocarbon removal three-in-one trapping cartridge (for nitrogen) × 1 pc

  • 0.32mm chromatographic column ferrule, Vespel graphite mixed material × 10 pc

Headspace Autosampler (75-position) Consumables:

  • 0.53µm quartz tube (30m) × 1 stick

  • Polyimide gasket ring (0.53 mm) × 5pcs /pack

  • Headspace aluminum crimp top caps with PTFE septa × 100pcs /pack

Laboratory equipment · Designed for precision
Labnics
Better instruments.
Better laboratories.
Start a conversation

Let’s build your next laboratory.

Explore dependable laboratory equipment and expert support for research, testing and quality-control environments.

Head OfficeUnit 2D Station House, 1 Pembroke Broadway, Camberley, Surrey GU15 3XD, United Kingdom.
Labnics © 2026. All Rights Reserved.
0