Flow Cytometer NFC-100 is equipped with dual laser systems emitting light at wavelengths of 488nm and 638nm. It features 6 fluorescence channels allowing for detailed characterization of cells. Our cytometer provides versatility in analyzing a wide range of cell types with particle detection ranging from 0.2 μm to 60 μm. It evaluates at 45,000/sec and processes 96-well plates within 30 minutes, ensuring high-throughput analysis.
Wavelength | 488nm, 638nm |
Laser | Semiconductor laser |
Laser Power | 488 nm & 638 nm laser: 20mW 40/60mW (Optional) |
Fluorescence Channels | 6 |
Filters Configuration | 488nm laser: 530/30 nm BP FITC, 585/42 nm BP PE, 700 BP Per CP/ PE-Cy 5, 785/55 nm BP PE-Cy7 638nm laser: 660/20 nm BP APC, 785/55 nm BP APC-Cy7 |
Optics | The excitation and receiving of solid spatial separation. No fiber conduction. Fixed optical path. |
Sensitivity of Fluorescence | FITC < 75 MESF PE < 55 MESF APC < 55 MESF |
FSC Sensitivity | 0.5 μm |
SSC Sensitivity | 0.2 μm |
Range of Particles | 0.2 μm to 60 μm |
Linear | ≥ 0.98 |
Resolution | CV ≤2% |
Carry-Over | ≤ 0.1% |
Detector | Avalanche Photodiode Detector(APD) |
Speed | 45,000 events/s; 96 - well plates/30min |
Minimum Sample Volume | 10μL |
Speed of Sample | 15 to 235 μL/Min |
Absolute Count | Volumetric method: Microspheres method |
Preheating Time | <4min |
Blending Mode | Whole plate; single pipe; interval mixing is set freely |
Tube Numbers of Loader | 40 tubes and 96 holes |
Type of Tube | Standard flow pipe(12 × 75mm, 5ml) 96 - well plates(F,U,V type) Centrifugal tube (1.5ml, 2ml) |
Capacity of Liquid Bottle | Waste liquid barrel 6L,Sheath liquid drum 6L,Cleaning liquid drum 1L |
Maintenance System | Liquid path maintenance automation |
Software | Software has an edition in English and Chinese With the function of automatic quality control detection, the software can draw the Levey-Jennings curve automatically Support to be connected with clinical LIS software, to facilitate data graphic transmission |
Feature of Software | Automatic saving mode against power failure Detection and analysis can run at the same time |
Compensation | Compensation Matrix List Quick Compensation Auto Compensation Auto Compensation Calculation |
FCS Format | FCS 3.0 |
Operational Environment | 10°C to 35°C, 15 to 80 % RH |
Computer Operating System | Win10 pro |
Voltage | 220 V, 50Hz |
Dimension (W × D × H ) | The host system: 44 × 43.5 × 52 cm The host system with leader: 57.2 × 53.3 ×52 cm Liquid tray: 44 × 32 × 45 cm |
Liquid Tray Weight | 7 Kg |
Host System Weight | 32 Kg |
Host System with Leader Weight | 38 Kg |
Labnics product catalog
Generated on: 15/02/2025
Labnics Ltd.
Unit 2D Station House, 1 Pembroke Broadway, Camberley,
Surrey GU15 3XD United Kingdom