Automatic Hematology Analyzer NAHA-100

AUTOMATIC HEMATOLOGY ANALYZER NAHA-100

Automatic Hematology Analyzer NAHA-100
AUTOMATIC HEMATOLOGY ANALYZER NAHA-100

Automatic Hematology Analyzer NAHA-100 is a single chamber unique hemoglobin test system, that offers throughput of 35 tests/hour. It uses electrical resistance method for counting, hemoglobin cyanide method and SFT method for hemoglobin measurement. Minimum sample volume required for venous and capillary mode is 9.8 µl and 20 µl for venous blood. In this unit 100000 sample results including histograms can be stored. Equipped with 8.4-inch colour TFT display, RS232 interface, internal thermal sensitive printer.

Automatic Hematology Analyzer NAHA-100
FEATURES
  • Single chamber automatic hematology analyzer
  • Comprised with 20 parameters and 3 colour histogram
  • Uses electrical resistance method for counting
  • Low sample consumption
  • Automatic diluting, mixing, rinsing and clog clearing
  • Automatic sample probe cleaning
  • Storage capacity of 100000 sample results including histograms
  • Equipped with 8.4-inch colour TFT display
  • RS232 interface, Internal thermal sensitive printer
  • Can be connected to external printer
  • PC connecting
SPECIFICATIONS
Throughput 35 tests/hour
Measuring principle electrical resistance method for counting, hemoglobin cyanide method and SFT method for hemoglobin measurement
Counting modes Venous, Capillary, and Prediluted
Sample volumes venous and capillary mode: 9.8µl
Pre-diluted: 20µl
Temperature 18°C-30°C
Display 8.4-inch colour TFT display
Storage Up to 100,000 sample results
Printer Built-in thermal sensitive printer
Parameters 20 parameters: WBC, Lymph#, Mid#, Gran#, Lymph%, Mid%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-CV, RDW-SD, PLT, MPV, PDW, PCT, P-LCR
Histogram 3 histograms: WBC, RBC, PLT
Precision
Parameter Linear range CV%
WBC (109/L) 0.0-99.9/td> ≤ 2%
RBC (1012/ L) 0.0-99.9 ≤ 1.5%
MCV (fL) 40-150 ≤0.5%
PLT (109/ L) 0-999 ≤ 0.4%
HGV(g/L) 0.0-300 ≤ 1.5%
Interface RS232
Power supply AC 220 ± 22 VAC, 50 ±1Hz
Packaging dimension (L×W×H) 33×38×43 cm
Weight 20 kg
APPLICATIONS

Automatic hematology analyzers are used for white blood cell counts, complete blood counts, reticulocyte analysis, and coagulation tests across medical labs, zoo, veterinarian labs, research labs, medical institutes, clinical laboratories etc.